Other command specifics, D other, Command specifics – Grass Valley Switcher Products User Manual
Page 122

122
Switcher Products — Protocols Manual
Section 4 — DPM CPL Protocol
Other Command Specifics
The bulk of the communications used for the switcher/DPM interface is via
parametric interchange, as indicated in Appendix B. This section tabulates
other commands used by the switcher/DPM interface.
Currently, the only other communications is the exchange of an on line
event while communications are initiated. The DPM must transmit an on-
Table 114. Switcher/DPM Parameters
Parameter Name
ID
Device
Type/Range
Switcher
DPM
PID_FRONT_VIDEO_SOURCE_LIST
810
Channel bit map:
0x00000001 = Chan 1
0x00000002 = Chan 2
0x00000004 = Chan 3
0x00000008 = Chan 4
0x00000010 = Chan 5
0x00000020 = Chan 6
0x00000040 = Chan 7
0x00000080 = Chan 8
(typically ORed to address
several channels at once)
8 bytes
Chan 1 first
1 - 48
all 8 bytes must be sent
even if bit not set in
device map
Rx SET
Tx SET
PID_VIDEO_BACK_SOURCE_LIST
813
PID_FRONT_KEY_SOURCE_LIST
811
PID_BACK_KEY_SOURCE_LIST
814
PID_FRONT_BACK_SELECT_LIST
816
8 bytes (as above)
Chan 1 first
0 = front
1 = back
PID_VIDEO_SOURCE
2642
Channel bit map:
0x00010000 = Chan 1
0x00020000 = Chan 2
0x00040000 = Chan 3
0x00080000 = Chan 4
0x00100000 = Chan 5
0x00200000 = Chan 6
0x00400000 = Chan 7
0x00800000 = Chan 8
ORed with
Back side bit map:
0x00000001 = Chan 1
0x00000002 = Chan 2
0x00000004 = Chan 3
0x00000008 = Chan 4
0x00000010 = Chan 5
0x00000020 = Chan 6
0x00000040 = Chan 7
0x00000080 = Chan 8
(refer to text)
short
1 - 48
Tx SET
Rx SET
PID_KEY_SOURCE
2643
PID_VIDEO_ON_SCREEN
819
Channel bit map
(refer to source list parameters
above)
1 boolean
(applies to all channels
specified in device field)
Tx SUB
Rx ISSUE
Rx SUB
Tx ISSUE
PID_KEY_ON_SCREEN
820
PID_VIDEO_ON_AIR (optional)
819
Rx SUB
Tx ISSUE
Tx SUB
Rx ISSUE
PID_KEY_ON_AIR (optional)
820
PID_CURRENT_EFFECT
886
0 = Effect Manager
short
any value
Tx SUB
Rx ISSUE
Tx SET
Rx SUB
Tx ISSUE
Rx SET
PID_EFFECT_POSITION
875
0 = Effect Manager
s15.16 in frames
Tx SET
Rx SET
PID_SYSTEM_NAME
917
0 = Effect Manager
exactly 16 chars
no terminating null
pad with spaces
Tx SUB
Rx ISSUE
Rx SUB-I
Tx ISSUE
Rx SUB
Tx ISSUE
optional:
Tx SUB-I
Rx ISSUE
PID_ETHERNET_ADDRESS
(optional - refer to Activity Check description)
3047
0 = Effect Manager
long
(refer to text)
Tx SUB-I
Rx ISSUE
Rx SUB-I
Tx ISSUE