beautypg.com

Grass Valley EDIUS Pro v.7.4 Reference Manual User Manual

Page 383

background image

Chapter 9 Audio Operations — Volume/Pan Adjustment

383

[Loudness Meter] Dialog Box

(1)

(5)

(6)

(2)

(4)

(8)

(7)

(10)

(11)

(13)

(9)

(12)

(3)

(1)

Loudness standard

Select the preset or the standard to be used for loudness measurement from the list.

(2)

Measurement target

Displays the sequence name and measurement group to be measured.

(3)

[Settings]

View the settings of loudness standards and set the output channels for L/R/C/LS/RS

channels.

“[Loudness Meter Settings] dialog box” (w page 384)

(4)

Switch measurement

group

The icon is displayed when two measurement groups have been set. Click this to switch the

measurement group.

(5)

History display

Display the measurement result as a chart.

The momentary value is displayed in green, and the short term value is displayed in light blue.

Click anywhere on the time scale and you can move to the clicked timecode position.

Press [I] or [O] on the keyboard anywhere on the time scale to set the In or Out point.

(6)

Level meter

Display the momentary (M) and short time (S) level.

(7)

Loudness range

Displayed when measurement is being performed by EBU R128.

A distribution based on the loudness measurement values of the history display is displayed.

When measurement ends, the loudness range and average level are displayed on the

distribution.

(8)

Measurement value

[Integrated]

Displays the average loudness value of the measured time in real time. Loudness values are

displayed in red when the target level is exceeded.

[Momentary]

Displays the average loudness value of 400 ms in real time.

[Short-term]

Displays the average loudness value of 3000 ms in real time.

[Loudness Range]

Displayed when measurement is being performed by EBU R128.

Display the width of loudness measurement values.

(9)

Trigger

[START]/[Pause]/[Continue]

Start, pause or restart measurement.

[RESET]

Reset the measurement results.

[In/Out]

Check this item to automatically measure between In and Out points during playback. The

timecode can be entered to change the In/Out points.

(10)

Scale

Change the scale of the Y axis of the history display when measurement is being performed by

EBU R128.

(11)

LU

Check this item to switch the display unit to LU.

Uncheck this item to switch the display unit to LUFS/LKFS.

(12)

[Play]

Play back timelines. Clicking this during playback stops playback.

(13)

[OK]

Close the dialog box.