Connections, Line connection – Westermo MA-47 User Manual
Page 5

12
6047-2002
Direction
Pin
CCIT V.11
no.
Description
Receiver
1
A’ (R+)
Receiver
2
B’ (R-)
Transmitter
3
A (T+)
Transmitter
4
B (T-)
Shield
Connections
Line connection
(5-Position screw-terminal)
Direction
Connection
CCITT V.24
Signal name
Code
I
2
103
TD/Transmitted Data
O
3
104
RD/Received Data
I
4
105
RTS/Request To Send
O
5
106
CTS/Clear To Send
O
6
107
DSR/Data Set Ready
–
7
102
SG/Signal Ground
O
8
109
DCD/Data Carrier Detect
I
20
108/2
DTR/Data Terminal Ready
I = Input O = Output on MA-47
Terminal connection (DCE)
(RS-232-C/V.24/V.28, 25-Polig D-sub, female)
Line connection
1) If shielded cable is used, connect the shield only at one end to avoid ground currents.
Look right for a section of rack RV-01 with
one MA-47 mounted.
Terminal connection to a 25-position D-sub(female) connector on MA-47.
Line connection to a 5-position detachable screw-terminal, which is mounted on the
male connector located at the rear of RV-01.
1
13
25
14
1
2
3
4
5
1 2 3 4 5
Twisted pairs
A’
B’
A
B
Transmitter
Receiver
MA-47
Receiver
Transmitter
Shield
1)
1
2
3
4
5
3
4
5
A/A’
B/B’
Transmitter/
Receiver
A/A’
B/B’
MA-47
Transmitter/
Receiver
2-wire
4-wire
Twisted pairs
RS-422
equipment
A
B
A’
B’
RS-485
equipment
Shield
1)
The definations R+/R–, T+/T– can be various
between different manufactures.