Tape Scale, OPS Top Mount Configuration

Installation by Hand Grip Applicator Tool

7.

Applying tape scale with the hand grip applicator tool

Once the applicator tool is configured with the adhesive backer exiting from the exit slot and steel tape

extending past the front tool roller, the scale is ready to be installed on the mounting surface.

Applicator tool correctly
configured for installation.

High guide edge face.

Applicator tool pressed
down and against high
guide edge face.

Slide tool along guide edge face with a slow even pressure motion until all of the tape is installed on
the mounting surface.

Be sure the adhesive backing film does not bunch up and jam inside the tool and exits freely from
the exit slot.

Applicator tool in motion against guide
edge face.