Fig. 51, 20w/6ohm x2, Sum2 – Nuvo ESSENTIA NV-E6GXS User Manual
Page 39
Grand Concerto
Control Pad
LOCAL SOURCE
SWITCH
NV-LSI24
CONNECT TO
AMPLIFIER
RLY+
RLY-
L-
L+
R-
R+
T
o
Amplifier
To Control Pad
T
oSpeakers
L-
L+
R-
R+
Model NV-LSI24
Mute Interface Module
The connection from the LSI24 is made through the
NV-IG8LSA RJ45 port on the back of the Control Pad
terminated with standard 568A. The connection at
the LSI24 requires the use of the Brown lead for
positive and Brown Stripe for negative.
NV-I8GLSA
NuVoNet
35
NV-LSI24 Local Source Interrupt (Fig. 51)
The Local Source Interrupt enables an amplified local audio source to override the Grand Concerto System and play through the
local zone in-wall speakers. The most common scenario for this is a television that would benefit from higher-quality speakers.
The back of the Grand Concerto Control Pad has two CAT5 inputs. One is labeled NuVoNet and is the CAT5 that runs to the EZ Port at
the head end. The other is labeled NV-I8GLSA. This is intended to react to the LSI24 accessory. It requires an RJ45 connection at
the Control Pad end and the Brown and Brown Stripe pair as a voltage trigger.
Note that the Local Source Interrupt is a passive non-amplified device. The signal sent to it must be amplified.
R
OUTPUT POWER
OUTPUT POWER
20W/6OHM X2
20W/6OHM X2
SYS ON
EXT. MUTE
L
L
R
VARIABLE
OUTPUT
FIXED
OUTPUT
SUM1
3033118
C
US
CONFORMS TO
UL STD.6500
CERTIFIED TO
CAN/CSA STD.E60065
NuVo Technologies Cincinnati Ohio USA
FUSE:T5 A
120V
60Hz 500W
MODEL NV-I8DM
SIX SOURCE EIGHT ZONE
AUDIO DISTRIBUTION SYSTEM
www.nuvotechnologies.com
OUTPUT POWER
OUTPUT POWER
OUTPUT POWER
20W/6OHM X2
20W/6OHM X2
20W/6OHM X2
TIP=L
RING=R
VARIABLE
OUTPUT
FIXED
OUTPUT
TIP=L
RING=R
VARIABLE
OUTPUT
FIXED
OUTPUT
TIP=L
RING=R
VARIABLE
OUTPUT
FIXED
OUTPUT
TIP=L
RING=R
VARIABLE
OUTPUT
FIXED
OUTPUT
TIP=L
RING=R
VARIABLE
OUTPUT
VARIABLE
OUTPUT
FIXED
OUTPUT
FIXED
OUTPUT
TIP=L
RING=R
TIP=L
RING=R
1
2
3
4
5
6
1
2
3
4
5
6
2
3
4
1
2
3
RS-232
CONNECT TO
NV-I8X
USE NV-SLC1
CABLE
CONNECT TO
NV-I8X
USE NV-SLC1
CABLE
CONNECT TO
NV-I8EZP1
USE NV-NC1
CABLE
USE CNLY WITH 250V FUSE
4
5
6
SUM2
6
7
8
OUTPUT POWER
20W/6OHM X2
ZONE 6
ZONE 6
ZONE 7&8
SYSTEM
ZONE TRIGGER OUTPUTS
SOURCE LINK
SOURCE INPUTS
ZONE 1
NETWORK
EMITTER OUTPUTS
DIGITAL LINK
ZONE 3
ZONE 4
ZONE 5
ZONE 2
PROGRAM
1
1
6
4
5
3
2
SOURCE STATUS INPUTS
R
R
R
5
1
MENU
OK
drift
SVR
1 of 9
Follow the Day
3:09 PM
3:48
1:28
Edge of Tomorr
Fig. 51
The positive and negative connection on the
LSI24 act as a relay relay switch between the
local source input and the audio coming from
the Grand Concerto System. When zone is
turned off, is routed to the speakers. When
the zone is on, the Grand Concerto audio goes
to the speakers.
Two or four conductor speaker wire from the
LSI24 to the zone speakers.
Speaker input from Grand Concerto
Amplified signal from the local zone source
The selected zone speaker output of the Grand Concerto
amplifier is wired directly to the LSI24
L