Operational Recommendations
4.1 Do not exceed corrosion limits. The CPM PP seal is designed to
resist corrosion by most chemicals. However, do not expose the
CPM PP materials of construction to products outside of their
corrosion limits. Consult your Flowserve Sales and Service
Representative for assistance.
4.2 Do not exceed the Pressure limits of the CPM PP seal, consult
Flowserve, Flow Solutions Division for assistance.
4.3 Do not exceed the temperature limits of the CPM PP seal. The
materials of construction are listed on the box label. Turn on
cooling water to the supply tank before start-up if the tank has
coils.
4.4 Do not start up or run the CPM PP seal dry. Buffer/barrier fluid
must be in the seal cavity at all times during pump operation.
For special problems encountered during installation, contact your
nearest Flowserve Sales and Service Representative or Authorized
Distributor.
4 feet (1.2 m)
maximum
1 foot
(30 cm)
minimum
Supply Tank
Assembly with
Cooling Coils
Dual CPM PP Unpressurized with Supply Tank
Figure 9