1nomenclature, Figure 1, Table 1 – Flowserve ISC2PP User Manual
Page 2
2
© Copyright 2000 Flowserve Corporation
1
Nomenclature
Notes: - Inboard stator (3A) is interchangeable with outboard stator (3).
- Inboard mating ring (3C) is interchangeable with outboard mating ring (3B).
- Inboard stator carrier (SC1) is interchangeable with outboard stator carrier (SC).
- Primary seal O-rings (P, P1, P2, P3, 6, 6A) are all the same size and cross section.
Figure 1
SL
6A
P3
SC1 RR
M
1
C
P
3C
3A
3
13
9
SC
P2
6
14
1B
C1
P1
G
G1
M1
11A
3B
K
CT
13A
B
11 10A
3
Outboard Stator
3A
Inboard Stator
3B
Outboard Mating Ring
3C
Inboard Mating Ring
C
Outboard Springs
C1
Inboard Springs
SC
Outboard Stator Carrier
SC1
Inboard Stator Carrier
P
Outboard Dynamic O-ring
P1
Inboard Dynamic O-ring
P2
Outboard Stator O-ring
P3
Inboard Stator O-ring
6
Outboard Mating Ring O-ring
6A
Inboard Mating Ring O-ring
G
Gasket
G1
Inner Gland O-ring
Table 1
1
Gland Assembly
B
Carbon Bushing
1B
Inner Gland
14
Rotor Carrier
RR
Retaining Ring
CT
Centering Tab
K
Centering Tab Cap Screw
SL
Sleeve Assembly
10A
Drive Ring
M
Outboard Vibration Dampner
M1
Inboard Vibration Dampner
9
Sleeve Collar
13
Cup Point Set Screw
13A
Quarter Dog Set Screw
11
Shaft O-ring
11A
Rotor Carrier O-ring
These instructions are written for trained, experienced technicians familiar with the basic
principles and tools involved in the installation, care and service of mechanical seals and seal
support systems. A complete reading of these instructions by personnel in contact with the
equipment is essential to safety. Incorrect installation, operation or maintenance can result in
personal injury or death to personnel and damage to the equipment.