beautypg.com

Scoreboard troubleshooting, Troubleshooting table, Section 3 – Daktronics TI-2002 Portable LED Timer User Manual

Page 13

background image

Scoreboard Troubleshooting

7

IMPORTANT NOTES

:

1. Disconnect power before doing any repair work on the scoreboard.

2. Allow only qualified service personnel access to internal display electronics.

3. Disconnect power when not using the scoreboard.

Troubleshooting Table

The table below lists potential problems with the scoreboard and indicates possible causes
and corrective actions. This list does not include every symptom that may be encountered,
but it does present several of the most common situations that may occur. Many of the
solutions offered below provide references to other sections within this manual or to
supplemental product manuals with further detail on how to fix the problem.

If a problem occurs that is not listed or that cannot be resolved using the solutions in the
following table, contact Daktronics using the information provided in Section 0.

Problem

Possible Cause

Solution/Items to Check

Scoreboard doesn’t light
and console doesn’t work

No power to the scoreboard

Check that the main circuit breaker

for the scoreboard is on.

Check that the scoreboard is

receiving 120 (or 230) V AC power.

No power to console

Ensure the console is plugged into a

120 (or 230) V AC power supply.

Swap the console with one known to

work correctly, and enter the proper

sport code to test. Replace console

if necessary.

Scoreboard digits don’t light,
but console works

No wired signal from console

Check that the scoreboard is

receiving 120 (or 230) V AC power.

Check that the red DS2 LED on the

driver lights up when sending

commands from the control console

(see Section 3.4).

No signal to driver

Check that the scoreboard is

receiving 120 (or 230) V AC power.

Check that the red DS2 LED on the

driver lights up when sending

commands from the control console

(see Section 3.4).

Swap the driver with one known to

work correctly and with the same

part number to verify the problem.

Replace if necessary (see Section

3.4).