BECKHOFF PHY User Manual
Page 9

Example Ethernet PHYs
Slave Controller
– Application Note PHY Selection Guide
6
Vendor / Device
ET1200
suitable
ET1100
suitable
IP Core
suitable
# Ports
Basic
HW
test
6
TX_CLK fixed
phase
7
PHY
addr.
8
PHY addr.
offset
9
Link loss
reaction time
Enhanced Link
Detection
Auto-TX-Shift
(IP Core only)
Comments
Renesas
µPD60610/µPD60611
-
-
X
1
no
0/8/16
/24
0
3 x RX_ER
(120 ns)
not necessary
required
Link loss reaction time configurable via MII management interface. Enhanced Link Detection cannot be
used with more than 1 port, because PHY addresses are not consecutive.
MI Link detection and configuration can only be enabled for tolerant IP Cores (starting with
V2.4.3/V2.04d and V3.0.2/V3.00c)
µPD60620/µPD60621
X
X
X
2
yes (Data sheet)
0/8/16
/24+1
0
3 x RX_ER
(120 ns)
not necessary
Link loss reaction time configurable via MII management interface; Set P1TXCL=0 for fixed TX_CLK
phase shift. Enhanced Link Detection cannot be used with more than 1 port, because PHY addresses
are not consecutive.
EtherCAT support starts with order number UPD60620AGK-GAK-AX / UPD60621AGK-GAK-AX.
MI Link detection and configuration can only be enabled for tolerant IP Cores (starting with
V2.4.3/V2.04d and V3.0.2/V3.00c)
SMSC/Microchip
LAN8187
-
-
X
1
no (Vendor)
0-31
0
provisionally
required
Link signal depends on PHY address.
LAN8700
-
-
X
1
no (Vendor)
0-31
0
provisionally
required
Link signal depends on PHY address.
LAN8710
X
1
no
0-7
0
provisionally
provisionally
STMicroelectronics
STE101P
-
-
X
13
1
1-31
16
provisionally
provisionally
PHY addr. 0 = Isolate. MDC clock transition required to complete reset phase (MI Link Detection and
Configuration required). Link signal depends on PHY address.
STE802RT1A/B
-
-
1
yes (Vendor)
1-31
16
provisionally
PHY addr. 0 = Isolate. MDC clock transition required to complete reset phase (MI Link Detection and
Configuration required).
Teridian
78Q2123
78Q2133
X
1
0/1
0
provisionally
provisionally
PHY addr. 0 = Broadcast. Only for single port devices, because only one PHY address can be used.
Texas Instruments
DP83620/
DP83630/
DP83640
X
X
X
1
yes (Vendor)
1-31
ET1100/
ET1200: 0
IP: 16
250 µs (conf.
to ~1.3 µs)
required
PHY addr. 0 = Isolate. Do not use SCMII mode. Use LED_LINK for link detection. Reset controller
required if clock sourced by ESC.
ET1100/ET1200: if port 0 is used, set PHY addresses to 1-4, PHY address offset to 0, add CPLD/uC
for address conversion.
IP Core: Set PHY address offset = 16 and use PHY addresses 16-19.
DP83848
X
X
X
1
yes
yes (Vendor)
1-31
ET1100/
ET1200: 0
IP: 16
250 µs
required
PHY addr. 0 = Isolate. Use LED_LINK for link detection.
ET1100/ET1200: if port 0 is used, set PHY addresses to 1-4, PHY address offset to 0, add CPLD/uC
for address conversion. X1 must be stable for min. 167 µs, need reset controller if CLK25Out is used
and resets are connected.
IP Core: Set PHY address offset = 16 and use PHY addresses 16-19.
DP83849
X
X
X
2
yes (Vendor)
0-31
0
250 µs
required
Do not use SCMII mode. Use LED_LINK for link detection. X1 must be stable for min. 167 µs, need
reset controller if CLK25Out is used and resets are connected.
TLK100
-
-
X
1
no
0-31
0
500 µs
required
required
TX_CLK phase changes at each link up.
TLK105
X
X
X
1
yes (Data sheet)
0-31
0
200 µs (conf.
to <10 µs)
required
Fast Link Down mode with 10 µs reaction time is supported (requires configuration via MII
management, default is 200 µs). Recommended configuration for Fast Link Down mode in CR3:
enable Bit 3 (RX Error count) and Bit 0 (Signal/Energy loss).
MI Link detection and configuration must not be used, because register 9 is PHY specific.
TLK106
X
X
X
1
yes (Data sheet)
0-31
0
200 µs (conf.
to <10 µs)
required
Fast Link Down mode with 10 µs reaction time is supported (requires configuration via MII
management, default is 200 µs). Recommended configuration for Fast Link Down mode in CR3:
enable Bit 3 (RX Error count) and Bit 0 (Signal/Energy loss).
MI Link detection and configuration must not be used, because register 9 is PHY specific.
TLK110
X
X
X
1
yes (Data sheet)
0-31
0
200 µs (conf.
to <10 µs)
required
Fast Link Down mode with 10 µs reaction time is supported (requires configuration via MII
management, default is 200 µs). Recommended configuration for Fast Link Down mode in SWSCR3:
enable Bit 3 (RX Error count) and Bit 0 (Signal/Energy loss).
MI Link detection and configuration must not be used, because register 9 is PHY specific.
13
MI link detection and configuration required.