Controls, Indicators, and Connectors

SAM1411 Installation and Use (6806800M91B)

38

3.2

LEDs

Table 3-1

describes the LEDs that can be found on the face plate of the board. The OOS, I/S,

ACT, and H/S LEDs can be controlled via IPMI. For more information, refer SAM1411 Control via
IPMI Programmer’s Reference
Guide.

3.3

Ethernet Connector (Out-of-Band)

One 10/100 Mbps Ethernet port is provided via the Ethernet connector on the face plate. It
allows external system managers to access the shelf manager.

Table 3-1 Face Plate LEDs

LED

Color

Description

Failure (OOS) LED

Red

Red: The shelf manager board is out-of-service.
Off: The shelf manager board is working properly.

Active (ACT) LED

Amber

Amber: The shelf manager board is active.
Off: The shelf manager board is in standby mode.

Hot Swap (H/S)

Blue

Blue (steady): The shelf manager board is ready to be extracted.
Blue (long blink): The board has been inserted or powered on and
is beginning the integration process. The eject handle switch is
closed.
Blue (short blink): The eject handle switch is open or an
extraction has been requested. The board is shutting down and
transferring control of the shelf to the other shelf manager board.
Off: The shelf manager board is not ready to be extracted. Do not
remove the board during this state.

In Service (I/S) LED

Green

Green: The shelf manager board is working properly.
Off: The shelf manager is not working properly or is initializing
after power-up.

Link Status /Activity

Green

ON – Data link is active between the PHY and an external
connection
FLASHING – Data is being transferred

Speed

Amber

ON – 100Mb/s mode is selected
OFF – 10Mb/s mode is selected