Setting Master on Distribution Headend
In order to create a data network in the building is necessary set MxU Master mode on device installed
on headend. Master mode is set with CoaxManager.
Connect Master to Coaxial Headend
Master Installed on headend establishes two connections:
Internet Connection
: To connect master modem to ISP provider is necessary to have a DSL
router, Docsis cable modem or similar devices which provide Internet access. Usually you need
a class Ethernet cable CAT-5 or CAT-6.
Connect to Coaxial Network
: You should connect master to coax network through a internal
diplexer filter of coaxData devices that suppresses interfering noise of coaxial header. Diplexer
function mixes TV and data signals with a minimal loss (<1dB) removing possible noise in the
working band (2 to 67,5 MHz) generated from the head. This connection is made through a
female connector "F".