HITEC X1 Pro DC/DC Multi-Charger User Manual
Page 40

40
discharge current setting
Toggle up
(▲) once to enter the “
DSCh
CURRENT
” screen. Toggle right
(►) once and the amperage value
will begin flashing. Toggle up
(▲) or down (▼) to change the
amperage value. Toggle right
(►) once to set the amperage.
discharge Voltage setting
(3.0-3.3v per cell)
Toggle up
(▲) once to enter the “
DSCh
VOLTAGE
” screen. Toggle right
(►) once and the voltage value will
begin flashing. Toggle up
(▲) or down (▼) to change the voltage
value. Toggle right
(►) once to set the voltage. Refer to page 7 for
recommended discharge voltages.
Terminal Voltage setting
(use at Your own risk)
Toggle up
(▲) once to enter the “
TVC=YOUR RISK!
” screen.
Toggle right
(►) once and the voltage value will begin flashing.
Toggle up
(▲) or down (▼) to change the voltage value. Toggle
right
(►) once to set the voltage.
Temperature cut-off
(when using optional temp sensor)
Toggle up
(▲) once to enter the “
TEM-
PERATURE CUT-Off
” screen. Toggle right
(►) once and the temperature value will
begin flashing. Toggle up
(▲) or down (▼)
to change the temperature value. Toggle
right
(►) once to set the temperature. The temperature can be set
between 20ºC and 80ºC.
Toggle up
(▲) once to enter the “
SAVE PROGRAM
” screen. Toggle
right
(►) once to save all of the settings previously entered.
baTTerY MeMorY (cont.)
DSCh CURRENT
2.2A
DSCh VOLTAGE
3.0V/CELL
TVC=YOUR RISK!
4.20V
TEMPERATURE
CUT-Off 50C
SAVE PROGRAM
ENTER
[ BATT MEMORY 1]
LiPo 7.4V(2S)
baTTerY MeMorY (cont.)
lITHIuM baTTerY MeTer