13/32"-

B

1

b

IF

\X

il—fl

'Vaa"

/

' IGNITOR

ASSEMBLY

K

/

\

Ig IGNITOR

(g BURNER

IGNITOR

ASSEMBLY

A91064

Fig. 12—Position of Ignitor to Burner

^8 OD

PRESSURE

TUBING

HEAT EXCHANGER
DIFFERENTIAL

PRESSURE
SWITCH

% OD

PRESSURE

TUBING

VZ

OD

DRAIN
TUBING
(TUBE PASSES

THROUGH
BLOWER SHELF)

■DRAIN

TRAP

A91113

Fig, 13—Upflow Furnace Pressure and Drain Tub­

ing Diagram

b. Reconnect edge connector at main control box on blower

shelf.

8. Check condition of gasket on cell inlet panel of burner

enclosure. Replace gasket if necessary. (See Fig. 10.)

9. Install gas control assembly in furnace.

10. Install diffuser and burner enclosure front.

11. Reconnect hot surface ignitor and flame sensor leads at

3-circuit connector. .

12. Refer to furnace wiring diagram and connect wires to gas

valve. (See Fig. 17.)

13. Reconnect pressure tubes to gas valve and burner enclosure.

Be sure tubes are not kinked.

14. Using backup wrench, install gas pipe in gas valve.

HEAT EXCHANGER
DIFFERENTIAL
FRESSURE
SWITCH

A91112

Fig. 14—Downflow Furnace Pressure and Drain

Tubing Diagram

15. Reconnect gas pipe at ground joint union.

16. Reconnect combustion-air pipe. Tighten hose clamps.

17. Replace blower door only.

18. Turn ON gas and electrical supplies.

19. Check furnace operation through 2 complete operating cycles.

Look through sight-glass in burner enclosure to check burners.
Burner flames should be clear blue, almost transparent. (See
Fig. 11.)

A WARNING

Never use matches, candles, flame, or other sources of
ignition to check for gas leakage. Use a soap-and-water
solution. Failure to follow this warning could result in a fire,
personal injury, or death.

20. Check for gas leaks.

21. After condensate starts to drain, check for condensate leaks.

22. Replace control door.

Step 5—Clean Condensate Drainage System

1. Disconnect 5/8-in. drain tube from bottom of inducer housing.

(See Fig. 13 or 14.)

2. Disconnect 7/8-in. drain tube from collector box. (See Fig. 13

or 14.)

3. Disconnect condensate drain line from drain trap at compres­

sion fitting.

4. Remove two 1/4-in. screws securing strap on drain trap to:

a. blower housing (upflow furnaces only).

b. bracket from cell panel (downflow furnaces only).

5. Remove drain trap/hose assembly from furnace and flush with

water until clean.

6. Flush external condensate drain line with water until clean.

7. Reassemble condensate drainage system by reversing items 1.

through 5.

Step 6—Hot Surface Ignitor

When removing the burner assembly, use care to avoid breaking

the hot surface ignitor. See Fig. 12 for the conect ignitor