Kits available, Instructions – Wilkerson 12 Series Bowl / Drain Kits User Manual
Page 2
Bowl Kits, Drain Kits, Bowl Guard Kits, Sight Gauge Kits and Force Fill Adapter Kits
83-959-000
Sight Gauge
(GRP-96-346)
Bowl Force Fill
Adapter
(LRP-96-304)
Torque:
1.4 - 1.7 Nm
(12 - 15 in-lbs)
Kits Available
Lightly grease with provided lubricant. (Grease is silicone free)
Inspect for nicks, scratches, and surface imperfections. If
present, reduced service life is probable and future replacement
should be planned.
Clean with lint-free cloth.
Description
Filter
Lubricator
Bowl Guard Kit
GRP-96-345
GRP-96-345
Body Force Fill
—
LRP-96-302
Adapter Kit
Sight Gauge Kit
GRP-96-346
GRP-96-346
Metal Bowl Kits
Manual Drain
GRP-96-348
—
Piston Drain
GRP-96-353
—
Sight Gauge &
GRP-96-349
LRP-96-306
Manual Drain
Sight Gauge &
GRP-96-352
—
Piston Drain
Sight Gauge &
—
LRP-96-305
Force Fill Adapter
Polycarbonate
Bowl Kits
Manual Drain
GRP-96-347
LRP-96-303
Piston Drain
GRP-96-351
—
Bowl Force Fill
—
LRP-96-304
Adapter Kit
No Drain
—
LRP-96-308
Drain Kits
Manual Drain
GRP-96-340
GRP-96-340
Piston Drain
GRP-96-354
—
Manual Drain
(GRP-96-340)
Nut
Torque:
1.1 to 1.7Nm
(10 to 15 in. lbs.)
O-ring
Nut
Torque:
1.1 - 1.7Nm
(10 - 15 in-lbs)
O-ring
Piston Drain
(GRP-96-351,
GRP-96-353,
GRP-96-354)
Instructions
1. Turn off air supply and depressurize the unit before
removing any parts.
Note: Lubricators with force fill devices require oil system
shut- off and disconnection. Filters with automatic drains
may require drain line disconnection.
CAUTION: Be certain that pressure is relieved on both
sides of any regulator in a system.
WARNING: Conversion or replacement of an old metal
bowl with a new plastic bowl will reduce the product
pressure / temperature rating. Be certain that the circuit
and environment does not exceed the lower ratings; and
that rating labels elsewhere on the product are replaced
with one describing the lower rating. Failure to do so
may cause property damage, injury or death.
2. After installation or service, apply system pressure and check
for air leaks. If leakage occurs, DO NOT OPERATE — conduct
repairs again.
Collar
(Hand Tighten
Plus 1/4 Turn)
Bowl Assembly
(Do Not Scratch
Internal Surface)
O-ring
Body
Assembly
(Internal
Surface
& Threads)
Manual Drain
O-ring
Body Force Fill
Adapter
(LRP-96-302)
Fill Button Assembly
Torque:
2.8 to 3.4Nm
(35 to 30 in. lbs.)
O-ring
O-ring
Body Force
Fill Adapter
(Hand Tight)
Fill Button Assembly
Torque:
2.8 to 3.4Nm
(35 to 30 in. lbs.)