beautypg.com

Kits available, Instructions – Wilkerson 12 Series Bowl / Drain Kits User Manual

Page 2

background image

Bowl Kits, Drain Kits, Bowl Guard Kits, Sight Gauge Kits and Force Fill Adapter Kits

83-959-000

Sight Gauge

(GRP-96-346)

Bowl Force Fill

Adapter

(LRP-96-304)

Torque:
1.4 - 1.7 Nm
(12 - 15 in-lbs)

Kits Available

Lightly grease with provided lubricant. (Grease is silicone free)

Inspect for nicks, scratches, and surface imperfections. If
present, reduced service life is probable and future replacement
should be planned.

Clean with lint-free cloth.

Description

Filter

Lubricator

Bowl Guard Kit

GRP-96-345

GRP-96-345

Body Force Fill

LRP-96-302

Adapter Kit

Sight Gauge Kit

GRP-96-346

GRP-96-346

Metal Bowl Kits

Manual Drain

GRP-96-348

Piston Drain

GRP-96-353

Sight Gauge &

GRP-96-349

LRP-96-306

Manual Drain

Sight Gauge &

GRP-96-352

Piston Drain

Sight Gauge &

LRP-96-305

Force Fill Adapter

Polycarbonate
Bowl Kits

Manual Drain

GRP-96-347

LRP-96-303

Piston Drain

GRP-96-351

Bowl Force Fill

LRP-96-304

Adapter Kit

No Drain

LRP-96-308

Drain Kits

Manual Drain

GRP-96-340

GRP-96-340

Piston Drain

GRP-96-354

Manual Drain
(GRP-96-340)

Nut
Torque:
1.1 to 1.7Nm
(10 to 15 in. lbs.)

O-ring

Nut
Torque:
1.1 - 1.7Nm
(10 - 15 in-lbs)

O-ring

Piston Drain

(GRP-96-351,

GRP-96-353,
GRP-96-354)

Instructions

1. Turn off air supply and depressurize the unit before

removing any parts.

Note: Lubricators with force fill devices require oil system
shut- off and disconnection. Filters with automatic drains
may require drain line disconnection.

CAUTION: Be certain that pressure is relieved on both
sides of any regulator in a system.

WARNING: Conversion or replacement of an old metal
bowl with a new plastic bowl will reduce the product
pressure / temperature rating. Be certain that the circuit
and environment does not exceed the lower ratings; and
that rating labels elsewhere on the product are replaced
with one describing the lower rating. Failure to do so
may cause property damage, injury or death.

2. After installation or service, apply system pressure and check

for air leaks. If leakage occurs, DO NOT OPERATE — conduct
repairs again.

Collar
(Hand Tighten
Plus 1/4 Turn)

Bowl Assembly
(Do Not Scratch
Internal Surface)

O-ring

Body
Assembly
(Internal
Surface
& Threads)

Manual Drain

O-ring

Body Force Fill

Adapter

(LRP-96-302)

Fill Button Assembly
Torque:
2.8 to 3.4Nm
(35 to 30 in. lbs.)

O-ring

O-ring

Body Force
Fill Adapter
(Hand Tight)

Fill Button Assembly
Torque:
2.8 to 3.4Nm
(35 to 30 in. lbs.)