Setup mode 1 (stationary programming) – Haltech IQ3 Data Logger Dash User Manual
Page 24

IQ3 Data Logger Dash Installation Manual
24
Setup Mode 1 (stationary programming)
Setup Mode 1 is used to program the unit without the need to operate the vehicle.
Entering Setup 1
1. Press and hold Button 1 (left button) for TWO shift light blinks – MEDIUM press
2. The Dash will display SETUP 1?
3. Confirm by pressing Button 1 for ONE shift light blink – SHORT press
The following are in the order in which the individual programming features will appear.
Setting as
Displayed on
Dash
Program
Setting Description
Programming
Command
Accept and
Advance
Accept and
Exit
BACKLIGHT
0 = Off
9 = Max Brightness
Short Press
Button 2 to
increase value
Short Press
Button 1
Long Press
Button 1
TACH PULSES
Number of pulses ignition
fires per revolution
V8=4
4 Cyl=2
0=Min
20=Max
Short Press
Button 2 to
increase value
Short Press
Button 1
Long Press
Button 1
SHIFT STEP
Programs RPM between
each shift light. Example:
If shift point is 5000 rpm
with a 100 step, first shi ft
light illuminates at 4600
RPM. Multiply your Step
setting by 4 and subtract
from Shift Point to
determine start of shift
light
Short Press
Button 2
Advances by 10
Medium Press
Button 2
Decreases by 10
Long Press
Button 2
Quickly advances
Short Press
Button 1
Long Press
Button 1
SHIFT GEAR X
X=Gear number
Program shift point for
each gear.
Short Press
Button 2
Advances by 10
Medium Press
Button 2
Decreases by 50
Long Press
Button 2
Quickly advances
Short Press
Button 1
Long Press
Button 1