Fig. 6—unit wiring diagram – Carrier INDUCED COMBUSTION FURNACES 58GFA User Manual

Page 6

background image

Fig. 6—Unit Wiring Diagram

A95464

LEGEND

ALS

AUXILIARY LIMIT SWITCH, OVERTEMP.
-MANUAL RESET, SPST-(N.C.)

BLWM

BLOWER MOTOR

CAP

CAPACITOR

CFR

COOLING FAN RELAY, SPDT

DSS

DRAFT SAFEGUARD SWITCH, SPST-(N.C.),
MANUAL RESET

EAC-1

ELECTRONIC AIR CLEANER CONNECTION (115 VAC)

EAC-2

ELECTRONIC AIR CLEANER CONNECTION (COMMON)

FL

FUSIBLE LINK

FU1

FUSE, 3 AMP, AUTOMOTIVE BLADE TYPE

FU2

FUSE FIELD INSTALLED

GV

GAS VALVE-REDUNDANT OPERATORS

HFR

HEATING FAN RELAY, SPST (N.O.)

IDM

INDUCED DRAFT MOTOR

IDR

INDUCED DRAFT RELAY, SPST-(N.O.)

ILK

BLOWER ACCESS PANEL INTERLOCK SWITCH,
SPST-(N.O.)

JB

JUNCTION BOX

LS

LIMIT SWITCH, AUTO RESET, SPST(N.C.)

OL

AUTO-RESET INTERNAL MOTOR OVERLOAD TEMP. SW.

PCB

PRINTED CIRCUIT BOARD (FURNACE CONTROL)

PL1

9-CIRCUIT CONNECTOR (PCB1)

PR5

PRESSURE SWITCH, SPDT

TRAN

TRANSFORMER (115V AC/24V AC)

JUNCTION

UNMARKED TERMINAL

PCB TERMINAL

FACTORY POWER WIRING (120 AC)

FACTORY CONTROL WIRING (120 AC)

FIELD POWER WIRING (120 AC)

CONDUCTOR ON PCB

FIELD WIRING SCREW TERMINAL

FIELD GROUND

EQUIPMENT GROUND

FIELD SPLICE

PLUG RECEPTACLE

NOTES:

322876-101 REV. A

1. Internally connected to equipment ground through mounting screw.

2. If any of the original equipment wire is replaced, use wire rated for 105°C.

3. Blower motor (BLWM) & Inducer motor (IDM) contain auto-reset

thermal overload switch.

4. Use only copper wire between the disconnect switch and the furnace

junction box (JB).

5. Symbols are electrical representations only6.

6. Auxiliary limit switch (ALS) used on downflow models only.

7. The transformer 24VAC winding is protected by a 3 AMP automotive

blade type fuse on the control board. A 24VAC short to ground during

installation, checkout, operation, service or maintenance could cause

this fuse to open. Do not replace the 3 AMP fuse with any other size fuse.

8. Blower motor (BLWM) adjustable OFF-DELAY. Factory set: 120 seconds

cut resistor: 180 seconds.

9. When CFR relay is energized, HFR relay is also energized.

FUSED DISCONNECT

SWITCH (WHEN REQ’D)

FU2

WHT

GRN

GRN

JB

IDM

ILK

TH

GV

PRS

FL

TR

PILOT

MGV

BRN

DSS

NO

C

NC

YE

L

LS

ALS

(WHEN USED)

NOTE #6

WH

T

RE

D

RE

D

BLU

BR

N

OR

N

BLK

RE

D

BLU

BLK

BLK

BLU

L1 PR1

PL1

WHT

BLK

TRAN

WH

T

RE

D

WH

T

NOTE #4

BLK

WHT

BLK

PR2 L2

HFR

CFR

LO

HI

COM

NOTE #9

EAC-2

EAC-1

SPARE-1

SPARE-2

IDR

1 4 7

2

5 8

3 6 9

SEC-2

SEC-1

PCB

FU1

3AMP
FUSE

GROUND

SCREW

REQUIRED

NOTE #1

NOTE #7

G

W

Y

R

C

NOTE #8

OL

START

BRN

BRN

CA

P

BLK (HI)

RED (LO)

WHT (

C

OM)

YEL (MED HI)

BLU (MED LO)

GRN

RED

BLU

MGV

ILK

L1

L2

TO 115V AC FIELD DISCONNECTIONS

NOTE #4

EQUIPMENT GROUND

L1

IDR

PL1-3

PL1-1

L1

EAC-2

SPARE-1

HEAT

SPARE-2

COOL

COM

EAC-1

START

OL

COM

HI

MED HI

MED LO

LO

BLWM

CAP

CFR

HFR

NOTE #9

IDM

PR-2

SEC-2

FL

ALS

PL1-4

FU1 PR-1

(WHEN USED)

NOTE #6

3A

SEC-1

FUSE

NOTE #7

LS

115V AC

TRAN

24V AC

HFR

LOGIC

TIME

DELAY

GV

TR

PL1-8

TH

DSS

PILOT

IDR

PL1-2

NOTE #9

C

PRS

NO

NC

PL1-6

IDR

Y

W

G

PL1-9

PL1-7

R

CFR

C

SCHEMATIC

DIAGRAM

BLWM

CONNECTION DIAGRAM

6