beautypg.com

Software controlled store/recall cycle, Switching waveforms – Cypress STK14C88-5 User Manual

Page 12

background image

STK14C88-5

Document Number: 001-51038 Rev. **

Page 12 of 17

Software Controlled STORE/RECALL Cycle

The software controlled STORE/RECALL cycle follows.

[19]

Parameter

Alt

Description

35 ns

45 ns

Unit

Min

Max

Min

Max

t

RC

[16]

t

AVAV

STORE/RECALL Initiation Cycle Time

35

45

ns

t

SA

[18, 19]

t

AVEL

Address Setup Time

0

0

ns

t

CW

[18, 19]

t

ELEH

Clock Pulse Width

25

30

ns

t

HACE

[18, 19]

t

ELAX

Address Hold Time

20

20

ns

t

RECALL

RECALL Duration

20

20

μs

Switching Waveforms

Figure 13. CE Controlled Software STORE/RECALL Cycle

[19]

t

RC

t

RC

t

SA

t

SCE

t

HACE

t

STORE

/ t

RECALL

DATA VALID

DATA VALID

6

#

S

S

E

R

D

D

A

1

#

S

S

E

R

D

D

A

HIGH IMPEDANCE

ADDRESS

CE

OE

DQ (DATA)

Notes

18. The software sequence is clocked on the falling edge of CE without involving OE (double clocking aborts the sequence).
19. The six consecutive addresses must be read in the order listed in the Mode Selection table. WE must be HIGH during all six consecutive cycles.