Operation – ETS-Lindgren 2087 Electric Powered Turntable 2 & 3 Meter Models (Archived) User Manual
Page 17

MODEL 2087 TURNTABLE SERIES
Operation
© EMC TEST SYSTEMS, L.P. – OCTOBER 2002
13
REV C – PN 399233
OPERATION
Please refer to the Model 2090 Positioning Controller manual if
you are unfamiliar with the operation of the unit. A 2090 manual is
included with each 2090 shipment and is also available for
download from our website: www.ets-lindgren.com.
With the assembly complete the Model 2090 controller will need
to be connected to the unit and power applied to both the motor
base and controller in order to continue. Refer to the electrical
installation section if you have questions about how to connect the
fiber optic cables.
Using the Model 2090 Positioning Controller check the CW and
CCW rotation in both directions by a few degrees. The position in
degrees increases (+) in the CW direction and decreases (-) in
CCW direction.
The turntable is calibrated at the factory to read out 360 degrees (+
or - 1 degree) for one complete revolution. If the table is not within
this accuracy, the unit can be re-calibrated per the instructions in
the “Turntable Encoder Calibration” section.
Archived 3/18/10