beautypg.com

Chauvet ZX-20LQ User Manual

Page 3

background image

Features

Removeable Head -To use the ZX-20LQ as a projector, the head may be removed. In order to

remove the head, simply unscrew the four screws holding the head bracket to the body of the unit

and unplug the connecting cable.

Function - The ZX-20LQ offers the user a choice of either static, continuous rotation or beat

activation. This feature is controlled by the 3 position switch on the bottom of the unit (located just

above the fan). This controls only the effects mirror.

Effect - The ZX-20LQ comes with an oil wheel. This effect can be changed to a water effect by inset-

ing the supplied glass water effect gobo. To insert the gobo, unscrew the gobo holder on the bottom

of the unit and slide the water effect gobo into the holder. Replace the holder in the unit and screw

in tightly.

Gobo - The ZX-20LQ is supplied with 3 interchangeable gobos. These gobos are superimposed on

the 29 dichroic oil wheel effects. To change/insert a gobo, remove the screw on the bottom of the

unit securing the gobo holder. Remove the gobo and replace with the desired gobo. Replace the

gobo holder in the ZX-20LQ and secure the screw tightly. The ZX-20LQ will accept custom gobos.

The gobo has a diameter of 41 mm. The image area has a diameter of 33 mm.

Installation / Mounting

Although this unit can be used in an upright position, it is recommended that, for safety purposes,

your lighting effect be properly mounted using a suitable hanging clamp and safety cable. CHAUVET

offers a range of items, which are ideal for safe mounting.

Replacing Lamps

1. Disconnect from main power supply before attempting to replace either lamps or fuse.

2. Ensure that the unit is sufficiently cool, before removing blown lamps.

3. Never touch new lamps with your fingers; use a tissue or a cloth.

In order to replace the lamp, disconnect from main power supply first, and unscrew the lamp

replacement cover, which is highlighted on the diagram (fig.1). Only use the appropriately rated

lamps as use of any other lamp type may cause the unit to be non-operational.

Due to the nature of halogen lamps it is vitally important that you do not touch the new replacement

lamp with your fingers, as this will reduce lamp life considerably. Once again a tissue or cloth can be

used for fitting the replacement lamp.

Finally before using, check that the lamp is housed correctly in the lamp holder and that the lamp

replacement cover has been screwed back into place.

If after replacement of the lamp, the unit is still not working then please contact CHAUVET

for servicing.