AC Mode
The UPS delivers power to the loads derived from the utility and maintains proper battery charge. It also 
regulates the output voltage to within a narrow range. 
 
On-Battery Mode
The UPS operates on battery when the line voltage or frequency has fallen outside the limits. Local 
users are alerted to this mode of operation by visual and audible indicators. The UPS provides power to 
the load from the battery and through its inverter and the output voltage and frequency of the UPS are 
regulated within a narrow range 
1. Switch 
On
Press the power switch on the top panel then the “power on” LED will light up.
 
2. Switch 
Off
Press again the power switch, the “power on” LED on the top panel will go off.
 
3. 
Cold Start / Start on Battery:
This UPS can be turned on even when AC is not present.
Press the power switch on the top panel then the “power on” LED will light up. 
 
ROUTINE MAINTENANCE AND STORAGE
ROUTINE MAINTENANCE
1.
Use dry soft clothes to clean the top panel and plastic parts. Do not use any detergent that contains 
alcoholic ingredient. 
 
2. 
The expected lifetime of the battery is around 3 years. Improper operation and harsh environment 
will reduce the actual lifetime. 
 
3. 
Unplug the UPS from power inlet if the UPS will not operate for long period of time.
STORAGE
1.
First turn off your UPS and disconnect its power cord from the wall outlet. Disconnect all cables 
connected the UPS to avoid battery drain. 
 
2. 
The UPS should be stored in a cool dry location.
 
3. 
Make sure the battery is fully charged before the UPS is stored.
 
4. 
For extended storage in moderate climates, the battery should be charged for 12 hours every 3 
months by plugging the power cord into the wall receptacle. Repeat it every 2 months in high 
temperature locations. 
TROUBLE SHOOTING
Problem
Possible Cause
Solution
The battery is not fully 
charged. 
Recharge the battery by leaving the UPS 
plugged in. 
The UPS does 
not perform 
expected 
runtime. 
The battery is slightly worn 
out. 
Contact CyberPower Systems at 
[email protected]
The on/off switch is 
designed to prevent 
damage by rapidly turning it 
off and on. 
Turn the UPS off. Wait 10 seconds and 
then turn the UPS on. 
The unit is not connected to 
an AC outlet. 
The unit must be connected to a 
220-240V 50/60Hz outlet. 
The battery is worn out.
Contact CyberPower Systems at 
[email protected]
The UPS will not 
turn on. 
 
Mechanical problem.
Contact CyberPower Systems at 
[email protected]
The circuit breaker is 
tripped due to overload. 
Turn the UPS off and unplug at least one 
piece connected equipment. Unplug the 
power cord of the UPS then remove the 
fuse compartment beneath the power inlet 
of the UPS and replace the blown fuse 
with a spare one. Lock the compartment 
back to the UPS. Connect power cord 
then turn the UPS on. Make sure that your 
spare fuse meets the specification. 
The battery is discharged
Allow the unit to recharge for at least 4 
hours. 
Outlets do not 
provide power to 
equipment 
The unit has been damaged 
by a surge or spike. 
Contact CyberPower Systems at 
[email protected]
The USB cable is not 
connected. 
Connect the USB cable to the UPS unit 
and an open serial port on the back of 
the computer. You must use the cable 
that came with the unit. 
The USB cable is 
connected to the wrong 
port. 
Try another USB port of your computer.
The unit is not providing 
battery power. 
Shutdown your computer and turn the 
UPS off. Wait 10 seconds and turn the 
UPS back on. This should reset the unit. 
PowerPanel
®
Personal Edition 
is inactive (all 
icons are gray). 
The serial cable is not the 
cable that was provided with 
the unit. 
You must use the cable included with the 
unit for the software. 
 
 
TECHNICAL SPECIFICATIONS
Model
BR 450ELCD
BR 650ELCD
BR 850ELCD
Capacity (VA)
450VA
650VA
850VA
Capacity (Watts)
270W
390W
510W
Input
Input Voltage Range
165-270Vac
Frequency Range
50/60 Hz+/-3Hz (Auto Sensing)
Output
On Battery Output 
Voltage 
Simulated Sine Wave at 230Vac +/-10%
On Battery Output 
Frequency 
50/60 Hz +/-1%
Overload Protection
Yes
Physical
Total # of UPS 
Receptacles 
Schuko*6 (3 for battery backup and surge ;3 for surge )
Dimensions(mm) 271(L)
x160.7(W)
x113.6(H)
Weight (kg)
4.4
5.5
6.4
Battery
Sealed Maintenance 
Free Lead Acid Battery
12V / 4.5Ah x1
12V / 7Ah x1
12V / 9Ah x1
Typical Recharge Time
8 Hours
Warning Diagnostics 
Indicators Power 
On
Audible Alarms
On Battery, Low Battery, Overload
Environmental
Operating Temperature
+32
°F to 104°F ( 0°C to 40°C )
Operating Relative 
Humidity 
0 to 85% NON-CONDENSING
Communication
PowerPanel
®
Personal
Edition Software
Windows2000/NT/XP/Server 2003/Vista/Mac OSX,Linux
Management
Auto-Charger Yes 
Auto-Restart Yes 
USB Interface 
Yes
Other Features 
Green Power 
Yes (Energy saving technology)
Batter Charger
External AAA/AA battery charger, connection via USB charger
DEFINITIONS FOR ILLUMINATED LCD INDICATORS
LCD Indication
Line mode
UPS Status Display
Capacity Display
Digital Value Display
Select SW
Press
Load 
Cap. 
Battery
Cap.
Input
Voltage
Output
Voltage
Run
Time
%
of Load
%
of Batt.
Initial
V X -- X V
X
V
1st
V X -- X V
X
V
2nd
V X -- X V
X
V
3rd
V X -- X X
V
V
4th
V X -- X V
X
V
5th(Return)
V X -- X V
X
V
Press >3sec
(Sound Disable)
V
X
V
X
-- -- -- -- -- -- --
Press >3sec
again
(Sound Enable)
V
X
X
X
-- -- -- -- -- -- --
(Overload) V
X
--
V
-- -- -- -- -- -- --
“V” : Illuminated, “X” : Not Illuminated, “--“ : Either
Battery mode
UPS Status Display
Capacity Display
Digital Value Display
Select SW
Press
Load 
Cap. 
Battery
Cap.
Input
Voltage
Output
Voltage
Run
Time
%
of Load
%
of Batt.
Initial
X V -- X X
V
V
1st
X V -- X X
V
V
2nd
X
V
--
X
V X V
3rd
X V -- X X
V
V
4th
X V -- X X
V
V
5th(Return)
X V -- X X
V
V
Press >3sec
(Sound Disable)
X
V
V
X
-- -- -- -- -- -- --
Press >3sec
again
(Sound Enable)
X
V
X
X
-- -- -- -- -- -- --
(Overload) X
V
--
V
-- -- -- -- -- -- --
“V” : Illuminated, “X” : Not Illuminated, “--“ : Either
For more information, visiact
CyberPower Systems B.V.
Flight Forum 3545 5657DW Eindhoven The Netherlands
Tel: +31 40 2348170, E-MAIL: [email protected]
CyberPower Systems Inc. (USA) 4241 12th Avenue East Suite 400 Shakopee, MN 55379, U.S.A.
Tel: +1 952 4039500, Fax: +1 952 4030009, E-MAIL: [email protected]
Entire contents copyright ©2008 CyberPower Systems B.V., All rights reserved. Reproduction in whole
or in part without permission is prohibited. PowerPanel
®
Personal Edition is the trademark of
CyberPower Systems Inc.
CyberPower warrants to you, the original purchaser, that CyberPower UPS will be free from defects in
design, assembly, materials and workmanship for two years ( battery is only one year) from the date of
original purchase. Any warranty services, please contact your local dealers or distributors.