Amico SSM Monitor Arms (Side to Side) User Manual
Page 7

www.amico.com
4
Section 2: Installation on Rail Systems
WARNING:
DO NOT attempt to mount/remove the arm from the
rail when loaded with any instrument
WARNING:
Support SSM arm until the set screws are tightened,
SSM am can slide down when set screws are not tightened.
NOTE:
Top and Bottom stoppers prevent the adapter from sliding
out of the MRS. To remove, the adapter must be removed from the
top with the Top Stopper pressed into the rail.
(Figure 2)
NOTE:
To slide the arm vertically in the channel, lift the arm near
the monitor and push up or down at the adapter.
(Figure 1)
1. Support the bottom of the arm with one hand, guide the
adapter into the top of the channel
(Figure 1)
2. Once the arm is at the desired height, tighten the two set
screws located at the bottom of the adapter using a 1/8’’ (3
mm) Allen Key. DO NOT release the SSM monitor arm until the
two set screws are tight. The SSM IT station may slide down the
rail if the set screws are not tightened.
MRS Rail: Length for representational use only
Top stopper
Bottom Stopper
MRS Rail
Standard MON-
Channel Adapter
SSM arm
1/8” (3 mm)
set screws
(Figure 1)
(Figure 2)
Mounting to the (MRS) Monitor Rail System