Great Plains YP825AR Operator Manual User Manual
Page 98

94
YP825AR
Great Plains Manufacturing, Inc.
401-923M
2014-06-17
Dry Fertilizer Troubleshooting
Problem
Cause
Solution
No Fertilizer
Flow, All
Rows
Hopper empty
Check / refill hopper.
Chain missing at one or more
drive stages
Check all five chains from ground drive to hoppers. See
page 110.
No Fertilizer
Flow, Some
Rows
Hopper plugged
Clean out any material clogging discharge port. See “Dry
Fertilizer Clean-Out” on page 99.
Shaft disconnected
Check couplers along final drive shaft.
No Fertilizer
Flow, One
Row
Applicator tube plugged with soil
Disconnect hose at top of applicator tube. Remove blockage
from below. Raise release height (page 61).
Applicator tube plugged with
fertilizer.
Disconnect hose at top of applicator tube. Remove blockage
from below. Use finer grained fertilizer, or dry out the fertilizer
if coagulation is the problem.
Low Flow
Augers set to Low Rate
(single-row planters only)
Set augers to High Rate (page 60).
Incorrect Transmission sprockets
Re-check Seed and Fertilizer Rate manual (401-923B).
Exchange DRIVING and DRIVEN sprockets as needed.
Field speed too high for
Transmission sprockets selected
Apply at a lower speed, or use a new sprocket pair for the
actual rate and speed. Metering (kg per revolution) is lower at
high speeds.
Ground drive wheel slipping
Check lowered tool bar height (page 18). Operate at a lower
field speed. Field conditions may be too wet for reliable meter
drive.
Meter flutes worn
Inspect meter flutes (page 41). Replace as needed.
High Flow
Augers set to High Rate
(single-row planters only)
Set augers to Low Rate (page 60).
Incorrect Transmission sprockets
Re-check Seed and Fertilizer Rate manual (401-923B).
Exchange DRIVING and DRIVEN sprockets as needed.
Field speed too low for
Transmission sprockets selected
Apply at a higher speed, or use a new sprocket pair for the
actual rate and speed. Metering (kg per revolution) is higher
at low speeds.
Fertilizer on
Surface
Release height too high
Lower release height (page 61).
Coulter depth too shallow