Dry Fertilizer Troubleshooting

Problem

Cause

Solution

No Fertilizer
Flow, All
Rows

Hopper empty

Check / refill hopper.

Chain missing at one or more
drive stages

Check all five chains from ground drive to hoppers. See
page 110.

No Fertilizer
Flow, Some
Rows

Hopper plugged

Clean out any material clogging discharge port. See “Dry
Fertilizer Clean-Out
” on page 99.

Shaft disconnected

Check couplers along final drive shaft.

No Fertilizer
Flow, One
Row

Applicator tube plugged with soil

Disconnect hose at top of applicator tube. Remove blockage
from below. Raise release height (page 61).

Applicator tube plugged with
fertilizer.

Disconnect hose at top of applicator tube. Remove blockage
from below. Use finer grained fertilizer, or dry out the fertilizer
if coagulation is the problem.

Low Flow

Augers set to Low Rate
(single-row planters only)

Set augers to High Rate (page 60).

Incorrect Transmission sprockets

Re-check Seed and Fertilizer Rate manual (401-923B).
Exchange DRIVING and DRIVEN sprockets as needed.

Field speed too high for
Transmission sprockets selected

Apply at a lower speed, or use a new sprocket pair for the
actual rate and speed. Metering (kg per revolution) is lower at
high speeds.

Ground drive wheel slipping

Check lowered tool bar height (page 18). Operate at a lower
field speed. Field conditions may be too wet for reliable meter
drive.

Meter flutes worn

Inspect meter flutes (page 41). Replace as needed.

High Flow

Augers set to High Rate
(single-row planters only)

Set augers to Low Rate (page 60).

Incorrect Transmission sprockets

Re-check Seed and Fertilizer Rate manual (401-923B).
Exchange DRIVING and DRIVEN sprockets as needed.

Field speed too low for
Transmission sprockets selected

Apply at a higher speed, or use a new sprocket pair for the
actual rate and speed. Metering (kg per revolution) is higher
at low speeds.

Fertilizer on
Surface

Release height too high

Lower release height (page 61).

Coulter depth too shallow

Increase coulter depth (page 63).