COMMUNICATIONS SETTINGS - INTERACT AT

Your INTERACT system can be controlled through the network or through the serial connection. You can
also connect a PTZ camera to the Camera port and use the Voice Tracking feature (not available on the
INTERACT Pro).

Network Settings

»

NOTE: Contact a Network Administrator for information on current network settings and
permissions.

C

hange

ip s

eTTings

1. Create a unique network name and enter it in the Network Name field - the default is

ClearOne.

2. If your network is DHCP enabled, the IP Address, Subnet and Gateway information will be filled in.
3. If your network is not DHCP-enabled or if you require a static IP address, clear the Use DHCP check box

and enter the IP Address, Subnet and Gateway addresses.

4. Select Use DNS if you have a Domain Name Server and want name resolution (to use a network name)

for your static IP address.

5. Set a Use Name and Password for access when connecting over IP. The default user name is:

clearone. The default password is:

interact - these are not case sensitive.

6. Click Ok to save the settings and close the window.

s

eTup

ip f

ilTering

• Enter specific IP addresses that will be allowed to access the INTERACT system.
• IP filters allow you to restrict access to your INTERACT system. Only computers with the specified IP

address can connect to INTERACT.

• You can specify a range of IP addresses by using zeros. For example, entering 192.168.105.0 will allow

any IP addresses in the 192.168.105.1 to 192.168.105.254 range to access the INTERACT system.

Serial Port Settings (AT Only)

C

onfigure

C

aMera

p

orT

1. If you are connecting a camera for voice tracking mode, set the Baud Rate to match the baud rate

indicated in the camera specifications.

2. Select Flow Control to enable hardware flow control.
3. Click Ok to save settings and close the window.

C

onfigure

C

onTrol

p

orT

1. Select the Control Port Baud Rate that matches the baud rate of the PC COM port or the control

device.

2. Select Flow Control to enable hardware flow control.
3. Click Ok to save settings and close the window.

l

earn

abouT

f

low

C

onTrol

• Flow Control is the regulation of the transmission and reception of data between two devices.

ClearOne recommends enabling Flow Control on the INTERACT system.