they require. If any control function or operating adjustment is not clear, review the applicable information
until you understand it thoroughly.

Have first aid available

Accidents can happen even when you are careful. Arrange your operator schedules so that a properly trained
person is always close by to render first aid. In addition, ensure that local emergency contact information is
posted clearly and in sight of the system operator.

Know potential crush and pinch points

Be aware of potential crush and pinch points on your system and keep personnel and equipment clear of
these areas.

Know electrical hazards

When the system electrical power is turned on, minimize the potential for electrical shock hazards. Wear
clothing and use tools that are properly insulated for electrical work. Avoid contact with exposed wiring or
switch contacts.

Whenever possible, turn off electrical power when you work on or in proximity to any electrical system
component. Observe the same precautions as those given for any other high-voltage machinery.

Keep bystanders safely away

Keep bystanders at a safe distance from all equipment. Never allow bystanders to touch specimens or
equipment while the test is running.

Wear proper clothing

Do not wear neckties, shop aprons, loose clothing or jewelry, or long hair that could get caught in equipment
and result in an injury. Remove loose clothing or jewelry and restrain long hair.

Remove flammable fluids

Remove flammable fluids from their containers or from components before you install the container or
component. If desired, you can replace the flammable fluid with a non-flammable fluid to maintain the proper
proportion of weight and balance.

Check bolt ratings and torques

To ensure a reliable product, fasteners (such as bolts and tie rods) used in MTS-manufactured systems are
torqued to specific requirements. If a fastener is loosened or the configuration of a component within the
system is modified, refer to the system and component assembly drawings (located on the System
Documentation CD) to determine the correct fastener, fastener rating, and torque. Overtorquing or undertorquing
a fastener can create a hazardous situation due to the high forces and pressures present in MTS test systems.

On rare occasions, a fastener can fail even when it is correctly installed. Failure usually occurs during torquing,
but it can occur several days later. Failure of a fastener can result in a high velocity projectile. Therefore, it
is a good practice to avoid stationing personnel in line with or below assemblies that contain large or long
fasteners.

Practice good housekeeping

Keep the floors in the work area clean. Do not leave tools, fixtures, or other items not specific to the test lying
about on the floor, system, or decking.

16 MTS Acumen™ Electrodynamic Test System

Safety