Install the HPU

Model 505.07/.11 SilentFlo™ HPU

Installation

35

Note

For hydraulic connections to air-cooled units, refer to the Air-Cooler to

SilentFlo

HPU Integration Product Information manual (MTS part

number 100-135-073).

The HPU requires connection to a suitable water supply, equipped with an
appropriate shutoff valve, to cool the hydraulic fluid. The differential
pressure required between the HPU water inlet and outlet connections is
0.24 to 0.34 MPa (35 to 50 psi). The maximum allowable water inlet
pressure is 0.83 MPa (120 psi).

The water supply must also be capable of maintaining water flow at a rate
listed in the following table.

A.

Connect the water supply to the HPU Water In port. Connect the
Water Out port to your drain/return line.

B.

A regulating valve must be adjusted according to your water
temperature.

4. Test the HPU.

A.

The unit is shipped with a plug in the filler cap. Remove the red filler
cap plug and install the screen in the fill port on the top of the reservoir.
The screen is shipped in the electrical enclosure.

B.

Rotate the power disconnect switch to the on (|) position.

C.

Pull the Stop button so it is released from its latched position. When
the Stop button is released, it enables the interlock circuit.

D.

Start the HPU by turning the High/Low/Start switch to the Start
position. When you hear the pump motor run, release the switch (it will
return to the Low position).

Note

The following step only applies when the HPU is first turned on after
the electrical power has been connected (see Step 2).

Incorrect motor rotation at high pressure for longer than 10 seconds can
cause severe damage to your HPU.

If the pressure,as observed on the pressure gage, does not increase within 10
seconds after High is selected, stop the unit.

W

ATER

I

NLET

T

EMPERATURE

M

ODEL

505.07

M

ODEL

505.11

10.0°C (50°F)

3.8 L/m (1.0 gpm)

7.2 L/m (1.9 gpm)

15.5°C (60°F)

4.9 L/m (1.3 gpm)

9.1 L/m (2.4 gpm)

21.1°C (70°F)

6.1 L/m (1.6 gpm)

12.1 L/m (3.2 gpm)

26.7°C (80°F)

8.3 L/m (2.2 gpm)

18.9 L/m (5.0 gpm)

32.2°C (90°F)

15.9 L/m (4.2 gpm)

49.2 L/m (13.0 gpm)