Model #TWO-CK

Power Extension Cable Management

Caution - Risk of Fire - Do Not Install Power Supply Cord Within the Wall Cavity

WARNING - Risk of Fire and Shock, Do Not Connect this Box to any Other Circuits or Outlets.

This kit is rated to 15AMP 125Volt AC only


Do not install this product near water, example, near a sink, tub, shower, swimming pool or laundry area.
Manufacturer is not liable for damages due to improper installation
methods not followed herein.
This product does not have built-in electronic circuitry for surge protection or A/C filtering.
It is recommended that this product be connected to a quality surge-protector/power conditioner for equipment protection.
Disclaimer.

HD-Products, Inc. the Manufacturer, it's agents, suppliers, and affiliates, shall not be liable for any damages, not limited to; misuse, acts of nature,

verbal and written expression and improper installation. Improper installation is determined such to include, not limited to, non-code compliant installation, product
modifications, alterations, adjustments, and substitutions of components or materials.
Limited 2-year Warranty from Manufactures Defects: Limited Two Year product warranty against manufacturer's defects.

Step 1

Location - Wall Cutout

PowerOUT - Determine TV wall mount bracket location.
Align between wall framing studs.
Use stud finder to determine in-wall obstructions
between framing both VERTICALLY and HORIZONTALLY.
Install in any direction, right/left, below, above,
next to TV wall bracket.

PowerIN - Align with upper PowerOUT within same stud-bay
no more than 60” apart.
Install within 60” from an existing power outlet or power-surge device.

Use supplied template sheet to mark area to cut out from drywall.
Use a level to maintain proper alignment.
Carefully use drywall saw or utility knife to cut along outside of line.

Do not exceed more
than 60” apart
(Unless installing
with Extension kit
part# CKRE)

Do not exceed more
than 60” apart from
existing outlet or
surge-protection unit

PowerOUT

PowerIN

HD-Products, Inc., intent to make this manual accurate and complete. However, HD -Products, Inc., makes no claim that the information contained herein covers all details, conditions, or
variations. Nor does it provide for every possible contingency in connection with the installation or use of this product. The information contained in this document is subject to change
without notice or obligation of any kind. HD-Products, Inc., makes no representation of warranty, expressed or implied, regarding the information contained herein.

HD-Products, Inc/LLC. PowerBridge Solution 3869 Norwood Dr. Littleton, CO 80125 USA

Customer Service: 855-755-9838 [email protected] www.PowerBridge1.com

Part No. TWOCK1014v2.0 2013 All Rights Reserved

Kit Includes:

72” Powerwire Prewired Dual PowerOutlet | 12” Powerwire Prewired PowerInlet
Pre-wired PowerConnectors | 72” PowerConnect Supply Cord | Template

PowerBridge can only be installed

within standard construction walls.

Only attempt installation within

2x4 or 2x6 wood/metal stud

framed wall.

!

!

If insulation exists,
remove or push
completely away
from the openings
to allow proper
flush mounting.

Need to extend the length?
Part# CKRE Extension Kit available

www.PowerBridgeSolution.com/CKRE.html

!

Wall Cut-out Template:
Lay against wall, use a level on edge
of paper to align.
Use a pencil to trace around edge.
Use drywall saw or sharp utility
knife cut on the edge of the line.
Remove drywall section.

2.1/4” x 3.5/8”
57mm x 93mm

Model #TWO

LEVEL

So Simple... You can do this!

PowerOUT

PowerIN

Tools for Installation

Not Included

Stud Finder

Flat-Blade

Drywall Saw

Level

CODE COMPLIANCY

SUPPORT

1)

NEC Article 334.30

Unsupported NM Cable

2)

NEC 2014 Article 400.7(A)(11)

Permitted use of cord / approved kit

using inlet to energize receptacle

Meets all US states and cities

adaptive to the National

Electrical Code (NEC)

allowing NM type building cable.