8 the main firmware version, The main firmware version, Table 14: initialization sequence delay time – Kramer Electronics VS-3232A User Manual
Page 48
The MENU Commands
43
43
9.7 Selecting the Initialization Sequence Delay Time for a Slave Unit
When several VS-3232A units are used together, it is necessary to set up the
delay time of each slave unit.
To configure the Initialization sequence delay time
1
:
1. Turn the machine OFF.
2. Set DIP 6 to OFF (Master unit).
3. Turn the machine ON.
The unit is now set to the Master Mode.
4. Set the delay time according to
, using the front-panel buttons and
the LCD.
5. Turn the machine OFF.
6. Set DIP 6 to ON (Slave unit).
7. Turn the Machine ON.
defines the initialization sequence delay time per unit in a
Master/Slave configuration setup
Table 14: Initialization Sequence Delay Time
The Number of the Slave unit in
the Sequence:
Required Turn-ON Time
[sec]
Notes
1
st
5
The delay time is set to 5 seconds
automatically
2
nd
10
Set via the Turn-ON menu
3
rd
15
4
th
20
9.8 The Main Firmware Version
The main firmware version menu shows information regarding the latest main
and Ethernet firmware versions, for example:
Main Firmware Version: 1.00
Ethernet Version: Use Config. Manager
This information lets you decide whether a firmware upgrade is required.
It is recommended to upgrade the firmware only after consulting with the
Kramer technical support staff
1 Turn-ON time