Faults with display (BD 530 Bp only)

Display

Remedy

ERR B

Check if foreign matters block the brushes; remove foreign
matter if required.

ERR T

Call customer service.

LOW BAT

Charging battery

ERR TEMP

Allow device to cool down.
Reduce brush contact pressure, if necessary.

HandsOff

Release the control handle and wait until the operating hours
or the battery status is shown in the display. After that, activate
the control handle again.

ERR REL

Turn off the switch for brush operation, turn off the switch for
the vacuum turbine, release the control handle, wait 3 seconds
and turn back on.
If the event recurs, call Customer Service.

Faults without display on the console

Fault

Remedy

Appliance cannot be started

Press control switch.
BD 530 Bp: Check battery; replace, if needed.
BD 530 Ep: Check if the mains plug is connected.
BD 530 Ep: Press in the overload fuse.

Insufficient water quantity

Check fresh water level, refill tank if necessary.
Check hoses for blockages; clean if required.

Insufficient vacuum perform-
ance

Clean the seals between dirt water reservoir and cover
and check for tightness, replace if required.
Clean the fluff filter.
Clean the vacuum lips on the vacuum bar, turn or replace
if required
Check if the suction hose and vacuum bar are chocked,
clean if required
Check the suction hose for tightness; replace if required.
Check if the cover on the dirt water discharge hose is
closed
Check the setting of the vacuum bar.

Insufficient cleaning result

Check the brushes for wear, replace if required.

Brushes do not turn

Press control switch.
Check if foreign matters block the brushes; remove for-
eign matter if required.
BD 530 Ep: Press in the overload fuse.

28