beautypg.com

Karcher B 140 R Bp Pack 400 Ah роликовая-дисковая User Manual

Page 27

background image

-

10

Faults with display

Display

Cause

Remedy

Seat switch broken

seat switch open! Seat contact switch has not been

activated.

The machine operates only if the operator is seated on the
seat.

Release accelerator!

release throttle? The gas pedal is depressed

when the main switch is on.

Take your foot off the accelerator before switching on the
main switch. If the fault recurs, call customer service.

Battery depleted ->
charge!

battery empty ->
charge!

The discharge level of the battery
has been reached. Cleaning
units can no longer be operated.
Drives and lighting can be acti-
vated.

Drive the machine to the charging station and charge the
battery.

Descargar totalmente
bateria!!

battery totally dis-
charged!

More than the permissible bat-
tery capacity has been utilised.
All units will be switched off. Ma-
chine is no longer ready for oper-
ations.

Manually unlock the front wheel brake (see "Operation /
push appliance"). Move the machine slowly to the charging
station. Charge battery.

Dirt reservoir full, clean-
ing stopped

sewage tank full
cleaning stops

Dirt water reservoir is full.

Empty the dirt water reservoir.

Operating hours set to 0! operating hours

set to 0!

Internal machine error while sav-
ing the number of operating
hours. During restart, the operat-
ing hours are always reset to 0.

None, for information.

Module temperature
high! Let it cool down!

moduletemp.
high let cool
down!

Controls are too hot.

Set main switch to “0”. Wait at least 10 minutes. Set main
switch to “1”.

Drive motor hot! Let it
cool down!

drive motor hot!
let cool down!

Drive motor has got overheated
due to a steep climb or locked
brake.

Set main switch to “0”. Wait at least 10 minutes. Set main
switch to “1”. If possible, use the unit only on level surfac-
es. If required, check the functioning of the immobilising
brake and driving pedal.

Contactor open!!

contactor open!! Defective controls.

Set main switch to “0”. Wait at least 10 minutes. Set main
switch to “1”.

Shut down, missing bus
supply

Shutdown, miss-
ing bus supply

Inform Customer Service

27

EN

This manual is related to the following products: