– 2

1 Electrodes
2 Suction hose (not included in the deliv-

ery)

3 Cable hook
4 Air outlet, working air
5 Suction head lock
6 Wheel
7 Air inlet, motor cooling air
8 Dirt receptacle
9 Steering roller
10 Suction head
11 Suction support
12 Floor nozzle (not included in the deliv-

ery)

13 Suction pipe (not included in the deliv-

ery)

14 Steering roller bow (NT 55/1 only)
15 Carrying handle
16 Filter cover
17 Push handle (NT 55/1 only)
18 Holder for suction pipe
19 Elbow (not included in the delivery)
20 Automatic filter dedusting
21 Main switch
22 Flat fold filter
23 Filter dedusting
24 Holder for floor nozzle or oven nozzle
25 Power cord
26 Nameplate

Caution
The flat pleated filter must always be in
place while vacuuming.

Static charge is deflected by providing
earthing to the connection nozzles. This
prevents the formation of sparks and cur-
rent shocks due to attachments (option)
with electrical conductivity.

To suck fine dust, you can also use an
additional membrane filter (optional).

Illustration

Release and remove the suction head.

Pull the membrane filter over the con-
tainer edge.

Insert and lock the suction head.

Illustration

To suck wet dirt, always remove the
membrane filter.

If wet dirt is vacuumed with the uphol-
stery or crevice nozzle, or if water is
sucked up from a container, it is recom-
mended to deactivate the "automatic fil-
ter cleaning" function.

If the maximum liquid level is reached
the appliance will turn off automatically.

In case of non-conductive liquids
(such as emulsion drilling fluids,
oils, and greases) the appliance is
not turned off when the container is
full. The filling level must be continu-
ously monitored and the container
must be emptied in time.

When suckung up oil or grease-contain-
ing liquid, we recommend installing the
upgrade kit for non-conducting media,
order no. 2.641-560.0 (optional).

After the wet vacuuming: Clean the flat
folded filter with the filter cleaning.
Clean the electrodes with a brush.
Clean the container with a damp rag
and dry it.

Illustration
Many suction hoses (optional) are
equipped with a clip system. All C-35/C-
DN-35 accessories can be connected.

Device elements

Start up

Anti-static system

Dry vacuum cleaning

Installing membrane filter (optional)

Wet vacuum cleaning

Remove the membrane filter.

General

Clip connection

13