Operation – Karcher NT 45-1 Tact Te M User Manual
Page 20
– 4
Illustration
Properly insert the connection socket in
the suction connection.
Push in the connection socket until it
locks into place.
Turn the suction connection with the
connection socket to the right to close it
tightly.
Note: The accurate fit is ensured by means
of a "bayonet connection".
Illustration
Release and remove the suction head.
Pull the paper filter bag out towards the
rear.
Pull the locking slide up and seal the pa-
per filter bag tightly when removing it.
Dispose off the used paper filter bag in
a dust-tight bag according to the statu-
tory provisions.
Insert and lock the suction head.
–
To suck wet dirt, first remove the paper
filter bag.
Illustration
Release and remove the suction head.
Put the disposal bag over.
Pull the opening of the disposal bag out
toward the back over the suction sup-
port and seal it tightly.
Tightly seal the disposal bag with clo-
sure strips underneath the opening.
Remove disposal bag.
Dispose of the disposal bag according
to the local provisions.
Insert and lock the suction head.
–
To vacuum wet dirt, always remove the
disposal bag (option).
Illustration
Release and remove the suction head.
Remove the membrane filter.
Insert and lock the suction head.
–
To vacuum wet dirt, always remove the
membrane filter (option).
–
If wet dirt is vacuumed with the uphol-
stery or crevice nozzle, or if water is
sucked up from a container, it is recom-
mended to deactivate the "automatic fil-
ter cleaning" function.
–
If the maximum liquid level is reached
the appliance will turn off automatically.
–
In case of non-conductive liquids
(such as emulsion drilling fluids,
oils, and greases) the appliance is
not turned off when the container is
full. The filling level must be continu-
ously monitored and the container
must be emptied in time.
–
After the wet vacuuming: Clean the flat
folded filter with the filter cleaning.
Clean the electrodes with a brush.
Clean the container with a damp rag
and dry it.
Illustration
The suction hose is equipped with a clip
system. All C-35/C-DN-35 accessories can
be connected.
Plug in the main plug.
Switch on the appliance at the main
switch.
Set the suction output (min - max) at the
rotary switch.
ƽ
Danger
Risk of injury and damage! The socket out-
let is only for the connection of power tools
to the vacuum cleaner. Any other use of the
socket outlet is not permitted.
Connect the mains plug of the electric
power tool to the vacuum cleaner.
Close the suction connection
Remove the paper filter bag
Removing the dust disposal bag
Remove the membrane filter.
General
Clip connection
Operation
Turning on the Appliance
Adjust the suction output
Working with electrical power tools
20