beautypg.com

Ec declaration of conformity, Technical specifications – Karcher IV 60-30 M B1 User Manual

Page 21

background image

– 9

We hereby declare that the machine de-
scribed below complies with the relevant
basic safety and health requirements of the
EU Directives, both in its basic design and
construction as well as in the version put
into circulation by us. This declaration shall
cease to be valid if the machine is modified
without our prior approval.

The undersigned act on behalf and under
the power of attorney of the company man-
agement.

Authorised Documentation Representative
S. Reiser

Alfred Kärcher GmbH Co. KG
Alfred-Kärcher-Str. 28 - 40
71364 Winnenden (Germany)
Phone: +49 7195 14-0
Fax: +49 7195 14-2212
Winnenden, 2013/05/01

EC Declaration of Conformity

Product:

Dry vacuum cleaner

Type:

1.573-xxx

Relevant EU Directives

2006/42/EC (+2009/127/EC)

2004/108/EC

94/9/EC

Applied harmonized standards

EN 55014–1: 2006+A1: 2009+A2: 2011

EN 55014–2: 1997+A1: 2001+A2: 2008

EN 60335–1

EN 60335–2–69

EN 61000–3–2: 2006+A1: 2009+A2: 2009

EN 61000–3–11: 2000

Applied national standards

-

Test report no.

70078790

TÜV SÜD
Ridlerstr. 65
80339 München

Marking:

II 3D 116°C

CEO

Head of Approbation

Technical specifications

Appliance de-
scription

IV 60/27-1

M B1

IV 60/30 M

B1

Type of protec-
tion

IP54

IP54

Container
capacity

60 l

60 l

Voltage

220-240 V

400 V

Frequency

1~ 50 Hz

3~ 50 Hz

Protection
(slow)

16 A

--

Maximum al-
lowed net im-
pedance

(0,361+

j0,198)

Ohm

--

Blower data
Power

2700 W

3000 W

Vacuum*

16,2 kPa

22,0 kPa

* with pressure limiting valve
Air quantity

56 l/s

64 l/s

Length x width x
height

920 x 640 x

1820

870 x 640 x

1820

Cable length

8 m

8 m

Protective class

I

I

Power cord: Or-
der No.

6.649-323 6.649-317

Power cord:
Type:

H07RN-F

3x2,5 mm

2

H07RN-F

4x2,5 mm

2

Suction hose

NW 51

5m

NW 51

5m

Typical operat-
ing weight

100 kg

90 kg

Storage temper-
ature

-10...+40

°C

-10...+40

°C

Humidity

30...90 %

30...90 %

Filter area

1,8 m

2

1,8 m

2

Ignition protec-
tion class
Values determined to EN 60335-2-69
Sound pressure
level L

pA

71 dB(A)

75 dB(A)

Uncertainty K

pA

1 dB(A)

1 dB(A)

Hand-arm vibra-
tion value

<2,5 m/s

2

<2,5 m/s

2

Uncertainty K

0,2 m/s

2

0,2 m/s

2

21