Suction capacity decreases, Dust comes out while vacuuming, Automatic filter cleaning is not working – Karcher NT 55-1 Tact Te User Manual
Page 17: Automatic filter cleaning cannot be switched off, Automatic filter cleaning cannot be switched on, Warranty, Accessories and spare parts, Warranty accessories and spare parts
– 5
Turn off the appliance and wait for 5
seconds, turn it on again after 5 sec-
onds.
Clean the electrodes as well as the
space between the electrodes with a
brush.
Remove blockages in the suction noz-
zle, suction tube, suction hose, or flat
pleated filter.
Exchange the paper filter bag.
Exchange the fleece filter bag (option).
Ensure the filter cover properly locks
into place.
Clean or replace the membrane filter
(special accessory) under running wa-
ter.
Replace the flat pleated filter.
Check drain pipe for leaks.
Illustration
Check/correct the correct positioning of
the flat fold filter.
Replace the flat pleated filter.
Clean the electrodes as well as the
space between the electrodes with a
brush.
Continuously check the filling level in
case of non-conductive liquid.
Suction hose is not connected.
Inform Customer Service
Inform Customer Service
The warranty terms published by the rele-
vant sales company are applicable in each
country. We will repair potential failures of
your appliance within the warranty period
free of charge, provided that such failure is
caused by faulty material or defects in man-
ufacturing. In the event of a warranty claim
please contact your dealer or the nearest
authorized Customer Service centre.
Please submit the proof of purchase.
–
Only use accessories and spare parts
which have been approved by the man-
ufacturer. The exclusive use of original
accessories and original spare parts
ensures that the appliance can be oper-
ated safely and trouble free.
–
At the end of the operating instructions
you will find a selected list of spare parts
that are often required.
–
For additional information about spare
parts, please go to the Service section
at www.kaercher.com.
Suction turbine does not start again
after the container has been
emptied
Suction capacity decreases
Dust comes out while vacuuming
Automatic shut-off (wet vacuum
cleaning) does not react
Automatic filter cleaning is not
working
Automatic filter cleaning cannot be
switched off
Automatic filter cleaning cannot be
switched on
Warranty
Accessories and Spare Parts
17
EN