FOREWORD

The design of model SBB75 76NE complies with the current edition of

ANSI Z21.10.3/CSA 4.3 as automatic storage or automatic circulating

tank type water heaters.

Installation diagrams are found in this manual. These diagrams will serve

to provide the installer with a reference for the materials and method of

piping necessary. It is highly essential that all water and gas piping be

installed as shown on the diagrams.

In addition to these instructions, the equipment shall be installed in

accordance with those installation regulations in force in the local area

where the installation is to be made. These shall be carefully followed

in all cases. Authorities having jurisdiction should be consulted before

installations are made.

ROUGH-IN DIMENSIONS

FIGURE 1.

The installation must conform to these instructions and the local code

authority having jurisdiction.

In the absence of local codes, the installation must comply with the following:

In the United States:

Current edition of the National Fuel Gas Code, ANSI Z223.1 / NFPA 54

and the National Electrical Code, NFPA 70;

In Canada:

Current edition of the Installation Code CAN/CSA-B149.1 and the

Canadian Electrical Code CSA C22.1.

These are available from Canadian Standards Association, 8501 East

Pleasant Valley Road, Cleveland, OH 44131 or National Fire Protection

Association, 1 Batterymarch Park, Quincy, MA 02269.

*INSTALL IN ACCORDANCE WITH LOCAL CODES

TOP VIEW

TABLE 3, GAS AND ELECTRICAL CHARACTERISTICS

All Models: Maximum supply pressure = 14.0 in. W.C. (3.48 kPa)

Minimum supply pressure, Natural gas = 6 in. W.C. (1.49 kPa).

Minimum pressures must be maintained under both load and no load (static and dynamic) conditions.

Recovery ratings are based on 80% thermal efficiency.

TABLE 1, DIMENSIONS

Units

A

B

C

D

E

F

G

H

J

K

L

M

Inches

CM

66 5/8

169.22

58 3/4

134.23

30 15/16

78.58

27 3/4

70.5

15 1/4

38.6

4

10.2

15 3/4

40.0

16

40.6

1 1/4

3.2

1 1/4

NPT

1/2

NPT

12 1/4

31.1

TABLE 2, RECOVERY RATINGS

Manifold Pressure

Electrical Characteristics

Type of gas

Inches W.C.

kPa

Voltz/Hz

Amperes

Natural Gas

4.0

1.12

120/160

<5

INPUT RATE

Recovery in US Gallons/hr or Liters/hr at Indicated Temperature Rise in Fahrenheit or Celsius

75,100 BTU/H

°F

30

40

50

60

70

80

90

100

110

120

130

140

GPH

243

182

145

122

104

91

81

73

66

60

56

52

22 KW

°C

17

23

28

33

39

44

50

56

61

67

72

78

LPH

920

688

549

460

392

344

306

277

251

228

213

199