beautypg.com

Configuring power management options – HP Insight Control Software for Linux User Manual

Page 24

background image

Go to

To

Reports

Power ManagementDisplay Power/Thermal

Data...

View reports

Reports

Power ManagementExport Report

Export reports

Power/Thermal tab > Power Management Actions > Change

Set the Power Cap and change the Power Regulator mode

Configure

Power ManagementConfigure Alerts...

Configure and schedule alerts

Options

Data Center Power Control Rules... or ToolsData

Center Power Control

> Define Rules tab

Define rules for responding to environmental emergencies and
other events requiring changes in data center power usage

Tools

Data Center Power Control or OptionsData Center

Power Control Rules...

> Invoke Rules tab

Execute rules to control power and cooling for the systems in the
data centers

Configuring power management options

Use Power Management Options to configure HP Insight Control power management settings and display
options.

With the Power Management Options you can:

Enable or disable

HP Insight Control power management

capabilities on managed systems. If disabled,

power data will not be gathered. This setting is global.

Provide sign-in credentials for iLOs through either HP Systems Insight Manager Global Credentials (if
all iLOs use a common set of credentials) or HP Systems Insight Manager System Credentials.

Configure a designated time range to keep historical data. The data is deleted automatically after the
specified time has elapsed. This setting is global.

Specify the default electrical derating percentage required by your local electrical code. This setting is
global.

Indicate whether to display temperature in Celsius or Fahrenheit. This setting is user specific.

Indicate whether to display power consumption in watts or Btu/hr. This setting is user specific.

To configure power management options:

1.

Click Options

Power Management.... The Insight Control power management Options page

appears.

2.

By default, HP Insight Control power management is enabled now. To disable power management,
clear the Enable HP Insight Control power management check box.

3.

Graph and Analysis Settings

provide the following options:

Temperature Unit of Measurement.

Select a unit of measurement for the temperature from the

list. This setting is user specific.

Power Unit of Measurement.

Select a unit of measurement for power.

Use GMT for all timestamps in the graphs.

Select this option to use Greenwich Mean Time

(GMT) when graphing data.

Cost of Power per kWh.

Enter the average cost of power per kilowatt-hour. This calculates the

cost of operation for the system and cooling. For ease of data entry, only one field is provided.
Use the Export option in the Power Regulator Actions section of the graphs if more cost analysis
is required. This field is used to calculate the cost and annual cost of operation for the system and
cooling.

Currency Type.

Enter the currency type. This option controls the display of cost information in the

Analysis section of graphs. The default value is USD. You can specify $, EUR, €, GBP, £, ITL, £,
JPY, ¥ or any other printable character set.

Cooling Multiplier.

Enter a cooling multiplier. This value represents the relative cost of cooling

the system compared to the cost of powering the system. The default value of 1.5 indicates that it
costs 1.5 as much to cool the system as it does to power the system. This value is multiplied by the

24

Basic procedures