Installation considerations, Rough in dimensions, Recovery capacities – American Water Heater HCG3 130T 300 User Manual
Page 10: Table 2, Gas line connection size table 1, Storage capacities table 3
10
table 2
Model
U.S. Gallons
Liters
ASmE
Standard
ASmE
Standard
(A)HCG-130300
130
119.9
492
453.8
(A)HCG-130400
130
119.9
492
453.8
(A)HCG-130500
130
119.9
492
453.8
figure 6
These designs comply with the current edition of the American National Standard for Gas Water Heaters, Volume III, ANSI Z21.10.3
/ CSA 4.3 as an automatic circulating tank water heater, and automatic storage water heaters.
rough in dimensions
gas line connection siZe
table 1
Model
Series
Natural Gas
Propane Gas
(A)HCG3 130T 300
100/101
1 1/4” NPT
1 1/4” NPT
(A)HCG3 130T 400
100/101
1 1/4” NPT
1 1/4” NPT
This table shows connections sizes only - see Table 5 on page 13 for minimum
required supply gas line sizes. Depending on the installed equivalent length,
and/or the number of appliances connected, the supply gas line size may have
to be increased beyond the minimum required sizes - see Gas Line Sizing on
page 37.
storage capacities
table 3
u. s. gallons/hr & liters/hr at temperature rise indicated
Model
Type of
Gas
Input
°F
20°F
30°F
40°F
50°F
60°F
70°F
80°F
90°F
100°F 110°F 120°F 130°F 140°F
btu/hr
kW
°C
11°C
17°C
22°C
28°C
33°C
39°C
44°C
50°C
56°C
61°C
67°C
72°C
78°C
(A)HCG 130T
300
Natural
300,000
88
GPH
1746
1164
873
699
582
499
436
388
349
318
291
269
250
Propane
LPH
6610
4406
3304
2644
2203
1888
1652
1469
1322
1201
1102
1017
945
(A)HCG3 130T
400
Natural
399,900 117
GPH
2328
1552
1164
931
776
665
582
517
466
423
388
359
332
Propane
LPH
8813
5875
4406
3525
2938
2518
2203
1958
1763
1602
1469
1356
1259
Recovery capacities are based on 96% thermal efficiency.
installation considerations
35°
20°
70°
18°
45°
45°
CL
EA
NO
UT
T &
P
VA
LV
E
G
AS
*1 1/2” NPT
WATER
OUTLET
FRONT
TOP
DRAIN V
AL
VE
INTAKE AIR
4 INCH PVC
VENT
4 INCHPVC
FRONT
BACK
CLEANOUT
T & P
3/4” NPT
DRAIN
1 1/2” NPT
WATER INLET
4” PVC
VENT CONNECTION
(exhaust elbow)
4” PVC
INTAKE AIR
CONNECTION
1 1/4” SUPPLY GAS
CONNECTION
33.12” (84.1 cm)
OUTSIDE
DIAMETER
4.86”
(12.34 cm)
50.77”
(129 cm)
75.50”
(191.8 cm)
69”
(175.3 cm)
69”
(175.3 cm)
12”
(30.5 cm)
* Center line of water outlet on top of the water heater is 7 inches from the front edge of the water heater.
WATER
OUTLET
HEIGHT
63 INCHES
(160 cm)
CONDENSATE
DRAIN CONNECTION
1/2 INCH PVC
recoVery capacities