Installation and operation (continued), Maintenance – Blue Angel Pumps ESU82 User Manual
Page 2
2
Operating Instructions and Parts Manual
Installation and
Operation (Continued)
Do not handle pump with wet
hands or when standing in
water or on a damp surface
when the unit is operating or fails to
operate. Always disconnect pump
power cord from power source before
handling.
6. Plug the power cord into a ground-
ed 120-volt AC power outlet. The
pump will start operating as soon as
the power cord is plugged into the
power outlet.
7. The pump will remove water down
to 1/8 inches of the hard surface the
pump was placed on.
8. The pump should be turned off
once the water level reaches the
1/8-inch mark.
Do not
allow
pump to run dry. The shaft seal depends
on water for lubrication. Operating
pump without water will damage the
shaft seal and cause pump failure.
Maintenance
Always disconnect electric
supply before attempting to
install, service, relocate or perform any
maintenance. Failure to do so could
result in fatal electrical shock.
Minimal service is required for this
pump. If pump should fail to operate,
perform the following troubleshooting
guidelines:
1. The motor housing of the
pump is completely sealed
and requires no service.
Disassembly of the motor
housing or alteration of the power
cord could result in fatal electrical
shock.
2. Verify pump is operating correctly.
a. Disconnect pump from power
source.
b. Disconnect discharge hose from
pump.
c. Immerse pump in a bucket or tub
of water.
d. Plug power cord into a grounded
120 volt AC power outlet. If
pump operates correctly proceed
to step #3. If pump does NOT
operate, unplug power cord and
proceed to maintenance guide-
line item 4 in this section.
3. Verify discharge hose is correctly
installed.
a. Connect hose to another water
source such as a faucet. If water
flows through hose, proceed to
step 3b. If water is restricted, ver-
ify discharge hose is unwound.
Remove all kinks, bends or
obstructions in hose.
b. Verify pumping height does NOT
exceed 25 feet (See Figure 1). If
pumping height is greater than
25 feet, this pump will NOT work.
4. Periodic cleaning of pump is
required to maintain performance
of the pump. Follow the cleaning
steps listed below:
a. Unplug the power cord.
b. Remove the 3 screws at the bot-
tom of the pump.
Figure 1 Water Level
25 Ft. Max.
Water Level
c. Remove the volute cover. Note
the alignment marks.
d. Remove the gasket. Note how
the openings in the gasket align
with the openings in the pump
base.
e. Remove the debris and make sure
the impeller turns freely.
f. Replace the gasket making sure
the openings are aligned.
g. Replace the volute cover.
h. Replace the 3 screws.
www.blueangelpumps.com