Warner Electric TCS-200-1H User Manual
Page 4
4
Warner Electric • 800-825-9050
P-2003-2 • 819-0420
o 1. If you are using a PLC or an
external power supply with this control, you must
enable the isolation of the control.
o 2. The TCS-200-1 can not operate a single brake
or brakes that require more than 4.25 amps
continuous.
o 3. The TCS-200-1H can not operate a single
brake or brakes that require more than 5.8 amps
continuous.
This Installation and Operation Manual has been
arranged for the systematic installation and start-up
of your tension control system. To achieve the best
possible results, we recommend checking off each
completed step in the space provided before
proceeding to the next step.
Sample
o Attach the TCS-200 control chassis to the
mounting surface and secure with mounting
hardware.
Check box after completing each step.
Control Mounting
o 1. Determine a suitable location for the control to
be mounted. Consideration should be given to
whether the front panel adjustments will require
access by the operator.
o 2. Using the dimensional data supplied in Figure
1a and Figure 1b, drill four mounting holes using
a #16 drill if #8 through-bolts are used. For #8
capscrew mounting, use a #29 drill and tap holes
for #8 screws. Templates for hole drilling are
found on page 21.
o 3. Attach the TCS-200-1 or TCS-200-1H control
chassis to the mounting surface and secure with
mounting hardware.
Note: The control chassis has been designed to
accommodate two half-inch conduits for wiring when
the control is mounted to the machine frame.
Auxiliary Inputs
• Brake Stop – Applies full voltage to the
connected brakes. Active high input
•
Brake Run – Voltage to the brake is controlled by
any of the sensor inputs and/or the front panel
tension adjust. Active high input.
•
Brake Off – Removes output current to the brake.
Puts the brake at zero current level. Active high
input.
Note 1: The remote input signal for these functions
requires a minimum contact rating of 20 VDC at .01
amps and a maximum of state leakage current less
than 100 micro-amps.
Note 2: The remote switch input overrides the front
panel switch.
Front Panel
•
Tension Adjust – Provides current adjust to the
brake from 0 to 100%. In the remote and
analog input mode, provides for maximum output
level set to the brake.
•
Brake Mode Switch –
Modes: "stop"-brake full on
"run" -normal operation
"off" -brake off
Indicators (Front Panel)
•
Green LED indicates AC power has
been applied to the control.
• Red LED indicates there is a short on the output.
Turn the front panel switch "off" to reset the short
circuit.
General
The control chassis must be considered NEMA 1
and should be kept clear of areas where foreign
material, dust, grease, or oil might affect control
operation.
Potentiometers (supplied by the customer)
•
Remote Torque Adjust
1,000 ohms, 10% tolerance, .5% linearity,
.5 watts, linear taper
•
Roll Follower – 1,000 ohms, 10% tolerance, .5%
linearity, .5 watts, linear taper