Timing Adjustment

Refer to the timing label enclosed. See Figure 3.

Figure 3

Maintenance

1. For reliable operation, the lens should be

cleaned periodically. Cleaning intervals may
vary, depending on installation environment,
from several times a year to several times a
day. If sensitivity adjustment is not at maximum
(or scanner is used at or near its maximum
range). more care must be taken to keep the
lenses clean.

Note: Enclosure is gasketed. Keep the cover
secured firmly during operation to prevent dirt
and smudge from building up on the inside of
the lens and photoelectric components.

2. To assure reliable operation, periodically check

tightness of the scanner mounting.

3. On high cycle rate applications using relay out-

put, the relay may require periodic replace-
ment.

Part Numbers

The part number lists below include complete
units, as well as individual components. If a com-
plete unit with head, base and output device is
required, please refer to the “Complete
Retroreflective Units” list. If only part of the unit is
to be replaced, refer to the “Modules and
Options” list.

Complete Retroreflective Units

Modules and Options

MCS-852

TRIAC

MCS-851

OPEN

COLLECTOR

MCS-850

RELAY

120

120

120

VAC

VAC

VAC

60/50 HZ.

60/50 HZ.

60/50 HZ.

SP

SP

LOAD

VAC

(-) (+)

DCV

C

NO

NC

Light
Oper.

Adj.

Dark
Oper.

Adj.

Delay Pull

S1, S4, S6

T1

S4, S6

T1

Delay Drop

S6

T1

S1, S6

T1

Delay
Pull/Drop

None

T2. T1

S1

T2, T1

One Shot

S1, S3, S6

T1

S3, S6

T1

Delay
One Shot

S1, S3, S4,

S5, S6

T1, T2

S3, S4, S5,

S6

T1, T2

Switched On Positions

Low Timing Range-Switches S7 & S8 Off .5 To 5.0 Sec.
High Timing Range-Switches S7 & S8 On 3.0 To 30 Sec.

If No Timing Function Is Required

Light Opera. - Switches S2 & S6 On
Dark Opera. - Switches S1, S2, & S6 On

Input

Voltage

Output
Device

Part

Number

120 Vac

Relay

7150-448-004

120 Vac

Open Collector

7150-448-020

120 Vac

Triac

7150-448-024

120 VAC Control w/Timing

7150-101-004

MCS-850
MCS-851
MCS-852

120 VAC Base

7150-101-013

Relay Output Module

7150-101-016

Open Collector Output Module

7150-101-017

Triac Output Module

7150-101-018

Dome

7150-101-019

Mounting Bracket

7150-101-020

Cable Adapter

7420-448-029

3” Diameter Retroreflector

610-8002-001

1 1/4” Diameter Retroreflector

610-8002-002