beautypg.com

Warner Electric PB-650 Pin Drive User Manual

Page 21

background image

21

Warner Electric • 800-825-9050

819-0485

PB-650 Brake

Drawing I-25730

How to Order:

1. Specify Bore Size for Item 2.
2. Specify Voltage for Item 5A.
3. Specify Inside or Outside Mounted for Item 5A.

Example:
PB-650 Brake per I-25730 - 90 Volt, 1" Bore

These units, when used in conjunction with the
correct Warner Electric conduit box, meet the
standards of UL508 and are listed under guide
card #NMTR, file #59164. These units are CSA
certified under file #LR11543.

1

4

2

3

6

5A

5A-1

5B

6

5B-1

7

7

Item

Description

Part Number

Qty.

1

Autogap Accessory

5181-101-010

4

2

Bushing*

1/2" to 1-5/8" Bore

180-0326 to 180-0344

1

3

Armature Hub

5207-541-002

1

4

Armature

5281-111-002

1

5A

Magnet - Inside Mounted

1

6 Volt

5369-631-003

24 Volt

5369-631-006

90 Volt

5369-631-005

5A-1

Terminal Accessory

5311-101-001

1

5B

Magnet - Outside Mounted

1

6 Volt

5369-631-009

24 Volt

5369-631-012

90 Volt

5369-631-011

5B-1

Terminal Accessory

5311-101-001

1

6

Mounting Accessory

5321-101-002

1

7

Conduit Box

5200-101-010

1

*See page 22 for specific part numbers.

This manual is related to the following products: