Warner Electric • 800-825-9050

819-0485

PB-500 Brake Heavy Duty

Drawing I-25550

How to Order:

1. Specify Bore Size for Item 1.
2. Specify Voltage for Item 4A, 4B, or 4C.
3. Specify Inside Mounted for Item 4A and

Outside Mounted (Offset) for Item 4B or
Outside Mounted (Flush) for Item 4C.

Example:
PB-500 Brake per I-25550 - 90 Volt, Inside
Mounted, 1" Bore

These units, when used in conjunction with the
correct Warner Electric conduit box, meet the
standards of UL508 and are listed under guide
card #NMTR, file #59164. These units are CSA
certified under file #LR11543.

3A

2

(Shipped Assembled)

1

5

4A-1

4A

4B-1
4C-1

4B
4C

2-2

2-5

2-3

2-4

2-1

5

3B

Item

Description

Part Number

Qty.

1

Armature Hub

1

3/4" Bore

5200-541-002

7/8" Bore

5200-541-003

15/16" Bore

5200-541-004

1" Bore

5200-541-005

1-1/8" Bore

5200-541-006

1-1/4" Bore

5200-541-007

2

Armature Assembly

5230-111-002

1

2-1

Armature

1

Segmented

5230-111-001

Solid

110-0076

2-2

Retainer Ring

748-0355

1

2-3

Autogap Spring

808-0412

1

2-4

Retainer Plate

748-0364

1

2-5

Screw

797-0028

3

3A

Mounting Accessory - I.M.

5102-101-001

2

3B

Mounting Accessory - O.M.

5300-101-008

1

4A

Magnet - I.M.

1

6 Volt

5300-631-002

24 Volt

5300-631-003

90 Volt

5300-631-005

4A-1

Terminal Accessory

5311-101-001

1

4B

Magnet - O.M. - Offset

1

90 Volt

5300-631-014

4B-1

Terminal Accessory

5311-101-001

1

4C

Magnet - O.M. - Flush

1

6 Volt

5300-631-009

24 Volt

5300-631-010

90 Volt

5300-631-011

Item

Description

Part Number

Qty.

4C-1

Terminal Accessory

5311-101-001

1

5

Conduit Box

5200-101-010

1