Warner Electric PB-650 Pin Drive User Manual
Page 19
19
Warner Electric • 800-825-9050
819-0485
PB-500 Brake Heavy Duty
Drawing I-25550
How to Order:
1. Specify Bore Size for Item 1.
2. Specify Voltage for Item 4A, 4B, or 4C.
3. Specify Inside Mounted for Item 4A and
Outside Mounted (Offset) for Item 4B or
Outside Mounted (Flush) for Item 4C.
Example:
PB-500 Brake per I-25550 - 90 Volt, Inside
Mounted, 1" Bore
These units, when used in conjunction with the
correct Warner Electric conduit box, meet the
standards of UL508 and are listed under guide
card #NMTR, file #59164. These units are CSA
certified under file #LR11543.
3A
2
(Shipped Assembled)
1
5
4A-1
4A
4B-1
4C-1
4B
4C
2-2
2-5
2-3
2-4
2-1
5
3B
Item
Description
Part Number
Qty.
1
Armature Hub
1
3/4" Bore
5200-541-002
7/8" Bore
5200-541-003
15/16" Bore
5200-541-004
1" Bore
5200-541-005
1-1/8" Bore
5200-541-006
1-1/4" Bore
5200-541-007
2
Armature Assembly
5230-111-002
1
2-1
Armature
1
Segmented
5230-111-001
Solid
110-0076
2-2
Retainer Ring
748-0355
1
2-3
Autogap Spring
808-0412
1
2-4
Retainer Plate
748-0364
1
2-5
Screw
797-0028
3
3A
Mounting Accessory - I.M.
5102-101-001
2
3B
Mounting Accessory - O.M.
5300-101-008
1
4A
Magnet - I.M.
1
6 Volt
5300-631-002
24 Volt
5300-631-003
90 Volt
5300-631-005
4A-1
Terminal Accessory
5311-101-001
1
4B
Magnet - O.M. - Offset
1
90 Volt
5300-631-014
4B-1
Terminal Accessory
5311-101-001
1
4C
Magnet - O.M. - Flush
1
6 Volt
5300-631-009
24 Volt
5300-631-010
90 Volt
5300-631-011
Item
Description
Part Number
Qty.
4C-1
Terminal Accessory
5311-101-001
1
5
Conduit Box
5200-101-010
1