Detroit Radiant Products Company HLV Series User Manual

Page 9

background image

9

HLV

Series

Model Number

Mounting

Angle*

Sides

Front

Behind

Top**

Below

HLV-40, HLV-50 [N, P]

9

9

4

47

45°

39

8

10

47

with 1 side shield

29

8

4

47

with 2 side shields

9

9

4

47

20 ft. from burner

7

7

4

30

HLV-60, HLV-75 [N, P]

9

9

4

48

45°

39

8

10

48

with 1 side shield

29

8

4

48

with 2 side shields

9

9

4

48

20 ft. from burner

7

7

4

30

HLV-80 [N, P]

11

11

4

48

45°

39

8

10

48

with 1 side shield

29

8

4

48

with 2 side shields

16

16

4

48

20 ft. from burner

7

7

4

30

HLV-90 [N, P]

12

12

4

54

45°

39

8

10

54

with 1 side shield

29

8

4

54

with 2 side shields

16

16

4

54

20 ft. from burner

7

7

4

30

HLV-100 [N, P]

14

14

4

66

45°

39

8

10

66

with 1 side shield

29

8

4

66

with 2 side shields

16

16

4

66

20 ft. from burner

7

7

4

30

HLV-110, HLV-120, HLV-125 [N, P]

18

18

4

72

45°

58

8

10

72

with 1 side shield

42

8

4

72

with 2 side shields

20

20

4

72

20 ft. from burner

7

7

4

30

HLV-140, HLV-150 [N, P]

24

24

6

81

45°

58

8

10

81

with 1 side shield

42

8

6

81

with 2 side shields

30

30

6

81

20 ft. from burner

11

11

6

44

HLV-170, HLV-175 [N, P]

34

34

6

92

45°

63

8

10

92

with 1 side shield

50

8

6

92

with 2 side shields

30

30

6

92

20 ft. from burner

11

11

6

44

HLV-180, HLV-200 [N, P]

41

41

6

94

45°

63

8

10

94

with 1 side shield

54

8

6

94

with 2 side shields

30

30

6

94

20 ft. from burner

11

11

6

44

1.0

Introduction

Clearance to Combustibles

Chart 1.2 •

Clearance to Combustibles in Inches (see Figure 1.2 for Mounting Angles)

*

Heaters mounted on an angle between 0° to 45° must maintain clearances posted for 0° or 45°; whichever is greater.

**

The top clearance of an exposed tube connection to combustibles is 18 inches.