Operation • Thermostat • Diagnostics • Operation Indicator Lights

Chart 4.1 •

Control Module Diagnostic Flash Codes

LED Flash Code

Fault Status

Steady ON

Control Fault

1 Flash

Air Flow Fault

2 Flashes

Flame - No call for heat

3 Flashes

Ignition Lockout

Figure 4.1

Operational Indicator Lights

Light 1* (amber)

Indicates High

Fire Mode

Light 2 (amber)

Indicates Low

Fire Mode

Light 3 (amber)

Pressure Switch

Operational Indicator Lights

Thermostat

NOTE: Different thermostats operate according to their particular features. Refer to thermostat
specifications for details.

HLV Series heaters require a 24V, two stage thermostat to operate. The burner control box is equipped
with a round terminal strip that accepts three (3) 1/4” insulated female spade terminals. Do not supply
120V to the 24V connection.

Theoretical Example: The thermostat is set to 65° F. The thermostat’s preset differential for
high fire mode is 3° F.

When the temperature drops below the setpoint of the thermostat (65° F), low fire will activate. If
the temperature continues to drop below the setpoint by another 3° F (62° F), high fire will activate
bringing the temperature back up to the thermostat’s setpoint.

Diagnostics

The controls will automatically lockout the heater system when an external or system fault occurs.

Lockout: If proof of flame is not established, a component failure occurs or blockages are evident, the

heater will enter hard lockout. If lockout occurs, the control can be reset by briefly interrupting
the power source. Refer to Chart 4.1 below for a description of the control module diagnostic
indicator flash codes.

*

Models with V-1SAO add-on are not equipped with high fire light.

NOTE: Flash code indicator light is located internally on the control module.