beautypg.com

Vacuum pump mounting – Detroit Radiant Products Company HLV Series User Manual

Page 22

background image

22

HLV

Series

3.0

Installation

Vacuum Pump Mounting

Vacuum Pump Mounting

Figure 3.3 •

NC-7 Vacuum Pump Mounting Details

Figure 3.4 •

PB Series Vacuum Pump Mounting Details

Chain Hanging Set

Vacuum

Pump

Power Box

Seam

Seam

Primary Damper

Safety

Chain

Tube and Reflector Hanger

Seam

Tube and Reflector Hanger

Primary Damper

Worm Clamp

Isolation Boot

Support Plate (field supplied)

Turnbuckle (P/N: V-TB) is
recommended for all
condensing pipe suspension
points for ease of slope
adjustment.

Vibration Isolators (field supplied)

Inlet Adapter

Threaded Rod
(field supplied)

Vacuum Pump

Vacuum Pump
Control Box

Secure pump assembly to support plate