Installation

Vacuum Pump Assembly and Mounting

Vacuum Pump Assembly and Mounting

Figure 3.2 •

Isolation Boot Placement

Prior to mounting the vacuum pump, ensure the building structure and support brackets have adequate
load characteristics to support the pump. Refer to Chart 3.1 below.

NOTE: The average sound level of PB Series vacuum pumps is between 60 and 63 DBA. If the
application requires a lower decibel level, relocation of the pump or a sound-deadening enclosure may
be necessary. Contact factory.

Vacuum Pump

Model

Vacuum Pump

Weight

NC-7

20 lbs.

PB-8

60 lbs.

PB-9

67 lbs.

PB-10A

73 lbs.

Chart 3.1 •

Vacuum Pump Weight

Following an engineered design layout:

1

Install vacuum pump as shown on plans. Ensure the pump is properly aligned with the system.

Allow an 8-in. to 12-in. space between the primary damper and the vacuum pump inlet adapter for

the isolation boot.

2

Using self-tapping sheet metal screws, mount the inlet and outlet adapters to the vacuum pump and

seal the joints with a high temperature sealant.

NOTE: The NC-7 pump does not require an inlet

adapter or isolation boots).

3

Install both isolation boots and secure with the hose clamps provided (Figure 3.2).

WARNING

!

Improper suspension of the heating system may result in collapse and being crushed.
Always suspend from a permanent part of the building structure that can evenly support
the total force and weight of the heater.

Primary Damper

Isolation Boot

Isolation Boot

Vacuum Pump

Inlet Adapter

Flue Vent

Outlet Adapter