Fault

Code

Displayed

Description

Cause

Lockout

type

Remedy

E15

Blower speed
abnormal.

Blower speed is 200RPM
below the target speed for
20 seconds.

Soft

Check the blower wire harness.
Change the blower.
Change the board.

1.
2.
3.

E16

Blower speed is 500RPM
above the target speed for 6
seconds.

E17

Machine starts or normal
combustion, but Blower
speed = 0 for last 3sec.

E18

Have Blower’s output signal
but the Blower speed = 0 for
last 400ms.

E19

Blower speed stuck > 3000
rpm

Soft

E20

Proportional
valve (PV) current
unusual.

Proportional valve Current <
Minimum.

Soft

Check the proportional gas valve
wire harness.
Change the board.
Change the gas valve assembly.

1.

2.
3.

E21

Proportional valve Current >
Maximum.

E22

Outlet
Temperature
Probe is Open
circuit.

Outlet Temperature
is < minimum defi ned
temperature.

Soft

Check temperature probes wire
harness.
Replace themperature probe.
Change the board.

1.

2.
3.

E23

Outlet
Temperature
Probe is Short
circuit.

Outlet Temperature
is > maximum defi ned
temperature.

E24

Inlet Temperature
Probe is Open
circuit.

Inlet Temperature is
< minimum defi ned
temperature.

E25

Inlet Temperature
Probe is Short
circuit.

Inlet Temperature
is > maximum defi ned
temperature.

E26

Tank Temperature
Probe is Open
circuit.

Tank Temperature
is < minimum defi ned
temperature.

E27

Tank Temperature
Probe is Short
circuit.

Tank Temperature
is > maximum defi ned
temperature.

E28

Ignition failure.

After a failure to detect
the fl ame during ignition,
the control will retry the
specifi ed number of times.
After the maximum failed
attempts, this fault is
declared.

Soft

Check the igniter wire harness.
Check igniter 120Vac voltage
supply during the ignition time.
Check the ignition rod. If it looks
dirty clean it using isopropyl alcohol
and a clean cloth.
Check the high voltage wiring
connection between igniter and
igniter rod for proper contact.

1.
2.

3.

4.

E29

Outlet water
temperature too
low.

Outlet water temperature <=
(setting temperature – 15°C)
for 60 seconds after fl ame
detected.

Alert

Check the outlet temperature probe.
Change the board.

1.
2.

TABLE 5