eLine Technology SOLAR-Charge Controller User Manual
eLine Technology Power suppliers
Renogy Charge Controller Model No. PWM10CC
1
30 AMP PWM CHARGE CONTROLLER MANUAL
Charge Controller Specifications
Technical Information (12/24V Auto Mode)
12V
24V
•
Rated Solar Input
30A
30A
•
Related Load
30A
30A
•
25% Current Overload
1 minute
1 minute
•
Load Disconnect
11.1V
22.2V
•
Load Reconnect
12.6V
25.2V
•
Equalization Voltage (30 minutes)
14.6V
29.2V
•
Boost Voltage (30 minutes)
14.4V
28.8V
•
Float Voltage
13.6V
27.2V
•
Temperature Compensation (mV/C)
-30mV/C
-60mV/C
•
Terminals
For wire sizes up to 6mm
2
•
Temperature
-35°C to + 55°C
•
Battery type
Lead Acid batteries, including AGM and Flooded
Table 1. Charge controller technical information
Quick Start Instructions
This section provides a brief overview of how to begin using your solar charge
controller. It is recommended that each user review the entire manual to ensure the best
possible performance as well as maximize years of worry-free service. It is highly
recommended that the connections be made in the following steps provided:
1. Mount the charge controller onto a clean, vertical flat surface. It is very important
to allow enough space both above and below the charge controller to ensure
maximum air flow.
2. After proper mounting is established, connect the battery to the charge controller
terminals. Be careful not to switch the polarities of the battery and do not allow
the bare wires to touch the metal casing of the charge controller.
3. Connect the solar (PV array) with the MC4 adapter kit cables. The green LED
indicator will light up if there is enough sunlight.
4. Optional: Connect the load if you have a 12VDC application. If the red LED
indicator light turns on, the battery capacity is low and needs to be charged
before completing the system installation.
eLineTechnology.com