beautypg.com

Extron Electronics RM 710M Installation User Manual

Rm 710m rack mounting kit • installation guide, Overview, Preparing and installing the rm 710m mounting kit

background image

Product Category

RM 710M Rack Mounting Kit • Installation Guide

Overview

This guide provides instructions for an experienced installer to mount and install the Extron TLP 710MV TouchLink

panel in

a standard 19-inch equipment rack, with 4U of vertical space. For complete instructions about installing and calibrating the
TouchLink panel, see the TLP 710MV and TLP 710TV User Guide, which is available on the Extron website
(

www.extron.com

).

Preparing and Installing the RM 710M Mounting Kit

To mount the TLP 710MV in any standard 19-inch equipment rack, follow these instructions:

1.

If necessary, disconnect any cables that are attached to the TouchLink panel.

2.

Run cables to the rack. Provide some slack in the cable for installing the TLP 710MV

3.

Secure the RM rack mount plate to the rack using the rack mount screws provided by the manufacturer of the rack.

Mounting the TLP 710MV

1.

Remove the faceplate from the TLP 710MV and
ensure that all the locking arms are flush with the
unit.

2.

Push the TouchLink panel through the opening in the
RM 710M.

3.

You may secure the TLP 710MV to the RM 710M using
the locking arms

Ñ

or mounting screws

Ц

.

С

Tighten the four screws for the locking arms
(two at the top and two at the bottom of the
TLP 710MV). As the screws tighten, the locking
arms rotate and clamp against the back of the
RM 710M, holding the TouchLink panel in place.
Do not overtighten the screws.
OR

Ö

Use four mounting screws (#6-32 x 0.375 inches)
to secure the TouchLink panel to the nut inserts in
the RM 710M. Do not overtighten the screws.

4.

Connect the cables to the back of the TLP 710MV.
If necessary, carry out an initial calibration of the
TouchLink panel, and replace the faceplate. For
complete instructions about cabling and calibration,
see the TLP 710MV and TLP 710TV User Guide.

Extron USA - West
Headquarters

+800.633.9876

Inside USA/Canada Only

+1.714.491.1500
+1.714.491.1517
FAX

Extron USA - East

+800.633.9876

Inside USA/Canada Only

+1.919.863.1794
+1.919.863.1797
FAX

Extron Europe

+800.3987.6673

Inside Europe Only

+31.33.453.4040
+31.33.453.4050
FAX

Extron Asia

+800.7339.8766

Inside Asia Only

+65.6383.4400
+65.6383.4664
FAX

Extron Japan

+81.3.3511.7655
+81.3.3511.7656
FAX

Extron China

+400.883.1568

Inside China Only

+86.21.3760.1568
+86.21.3760.1566
FAX

Extron Middle East

+971.4.2991800
+971.4.2991880
FAX

©

2011 Extron Electronics All rights reserved.

www.extron.com

68-2152-01

Rev. A

09 11

IMPOR

TANT

:

Refer to www

.extron.com for

the complete TLP 710 Series

user guide befor

e connecting

the pr

oduct to the power sour

ce.

Tighten screws to

rotate locking arms.

Secure RM 710M

to Rack

Screws (provided

by rack manufacturer)

Faceplate Snaps to Unit

(4 plcs. ea. side)

RM 710M

Secure unit with

mounting screws (4).

OR

2

1

4

3a

3b