Extron Electronics IN1508 User Guide User Manual
Page 62
![background image](/manuals/311897/62/background.png)
Command/response Table for SIS Commands (continued)
Command
ASCII Command
(Host to Unit)
Response
(Unit to Host)
Additional Description
Front panel locks (Executive mode)
NOTE: Lock mode 2 can be turned on and off only under SIS control.
Partially lock front panel
(lock mode 1)
1X
Exe1
]
Fully lock front panel
(lock mode 2)
2X
Exe2
]
Fully unlock front panel
(lock mode 0)
0X
Exe0
]
View lock status
X
X$]
Test patterns
NOTES:
•
Test patterns are available on IN1508 units that shipped after March 2007 and are firmware revision 2.30 or higher.
•
Changing the output rate or selecting a new input turns off the test pattern.
Turn a test pattern on or off
X2&
J
Tst
X2&]
Select
X2&
test pattern.
Example:
3J
Tst3
]
Select crop test pattern.
Turn test pattern off
0J
Tst0
]
View selected test pattern
J
X2&]
Resets
Reset all IN1508 settings
E
ZXXX
}
ZapXXX
]
Reset all settings and adjustments the factory
defaults.
Information requests
Query firmware version
Q
n.nn
]
Show the factory installed firmware controller
version.
Request part number
N
60-569-01
]
Information request
I
Chn
X!
•Pch
X!
•Std
X1&]
Chn is the input selected for the main window.
Pch is the input seletected for the PIP window
(0 when PIP is off).
Std is the autodetected input 1 through 4 (or 5
if low resolution) video standard.
NOTE:
X!
= Input number
1 through 8
X$
= Mute status
0 = mute off
1 = mute on
X1&
= Detected input signal standard (input 1 through 4 or 5):
0 = none
3 = NTSC 4.43
1 = NTSC 3.58
4 = SECAM
2 = PAL
X2&
= Test pattern:
0 = Off
2 = White field
1 = Alternating pixels
3 = Crop
IN1508 • Programming Guide
57