beautypg.com

Extron Electronics IN1508 User Guide User Manual

Page 62

background image

Command/response Table for SIS Commands (continued)

Command

ASCII Command

(Host to Unit)

Response

(Unit to Host)

Additional Description

Front panel locks (Executive mode)

NOTE: Lock mode 2 can be turned on and off only under SIS control.

Partially lock front panel
(lock mode 1)

1X

Exe1

]

Fully lock front panel
(lock mode 2)

2X

Exe2

]

Fully unlock front panel
(lock mode 0)

0X

Exe0

]

View lock status

X

X$]

Test patterns

NOTES:

Test patterns are available on IN1508 units that shipped after March 2007 and are firmware revision 2.30 or higher.

Changing the output rate or selecting a new input turns off the test pattern.

Turn a test pattern on or off

X2&

J

Tst

X2&]

Select

X2&

test pattern.

Example:

3J

Tst3

]

Select crop test pattern.

Turn test pattern off

0J

Tst0

]

View selected test pattern

J

X2&]

Resets

Reset all IN1508 settings

E

ZXXX

}

ZapXXX

]

Reset all settings and adjustments the factory
defaults.

Information requests

Query firmware version

Q

n.nn

]

Show the factory installed firmware controller
version.

Request part number

N

60-569-01

]

Information request

I

Chn

X!

•Pch

X!

•Std

X1&]

Chn is the input selected for the main window.
Pch is the input seletected for the PIP window
(0 when PIP is off).
Std is the autodetected input 1 through 4 (or 5
if low resolution) video standard.

NOTE:

X!

= Input number

1 through 8

X$

= Mute status

0 = mute off

1 = mute on

X1&

= Detected input signal standard (input 1 through 4 or 5):

0 = none

3 = NTSC 4.43

1 = NTSC 3.58

4 = SECAM

2 = PAL

X2&

= Test pattern:

0 = Off

2 = White field

1 = Alternating pixels

3 = Crop

IN1508 • Programming Guide