Procom BPF 3-...-200-sht User Manual
Bpf 3/ -sht
BPF 3/...-200-SHT
Band-Pass Filter for the 130 MHz Band
DESCRIPTION
High power base station shortened band-pass filter for the 116 - 146
MHz range.
Due to the use of large ø200 mm cavities a high Q is achieved, resulting
in a very narrow passband.
The large dimensions also mean a high power rating.
The SHT-version has only 600 mm cavity length.
Unloaded Q of a single cavity is approx. 3000.
High frequency stability on temperature and power.
19” mounting brackets are available as an option.
ORDERING DESIGNATIONS
TYPE
PRODUCT NO.
BPF 3/1-200-SHT
200000983
BPF 3/2-200-SHT
200001163
BPF 3/3-200-SHT
200001890
SPECIFICATIONS
ELECTRICAL
MODEL
BPF 3/1-200-
SHT
BPF 3/2-200-SHT
BPF 3/3-200-SHT
FREQ. RANGE
116 - 146 MHz
116 - 146 MHz
116 - 146 MHz
MAX. INPUT
POWER
350 W @
0.5 dB IL
150 W @
2.0 dB IL
350 W @
1.0 dB IL
150 W @
4.0 dB IL
350 W @
1.5 dB IL
150 W @
6.0 dB IL
INSERTION LOSS
Adjustable
0.5 - 2.0 dB
Adjustable
1.0 - 4.0 dB
Adjustable
1.5 - 6.0 dB
ATTENUATION
See figure 1
See figure 2
See figure 3
IMPEDANCE
Nom. 50 Ω
Nom. 50 Ω
Nom. 50 Ω
SWR
(at resonance)
< 1.5
< 1.5
< 1.5
MECHANICAL
TEMP. RANGE
RH 0-90% non-
condensing
–30° C →
+60° C
–30° C →
+60° C
–30° C →
+60° C
FREQ. STABILITY
Approx. 1.5
ppm/° C
Approx. 1.5
ppm/° C
Approx. 1.5
ppm/° C
CONNECTORS
N-female
N-female
N-female
DIMENSIONS
ø200 x 600
mm
L:200 x W:400 x
H:600 mm
L:200 x W:600 x
H:600 mm
WEIGHT
Approx. 4.6 kg
Approx. 10 kg
Approx. 14.5 kg
TYPICAL RESPONSE CURVES
Figure 1
TYPICAL RESPONSE CURVES
Figure 2
TYPICAL RESPONSE CURVES
Figure 3
PROCOM A/S reserve the right to amend specifications
without prior notice.
06/05/13